3D printed microtissue cassettes enabling high throughput proton radiobiological assays

Chih Tsung Yang*, I. Chun Cho, Ching Fang Yu, Edward Cheah, Tesi Liu, Yi Ping Lin, Sing Yu Hu, Jyun Wei Jheng, Ivan Kempson, Tsi Chian Chao, Sen Hao Lee, Eva Bezak, Benjamin Thierry*

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

Abstract

Background: The concept of Relative Biological Effectiveness (RBE) enables to translate the clinical experience for photon treatments to proton beam therapy. However, uncertainties in the proton RBE across the spread-out Bragg peak (SOBP) (typically assumed to be 1.1) may lead to suboptimal treatment plans and unwarranted toxicity to organs-at-risk. Herein, we report a reliable analytical method to determine the proton RBE in vitro along the SOBP and distal fall-off region. The 3D microtissue cassette enables the high throughput assessment of biological assays including clonogenic assay and γ-H2AX assay following a single proton irradiation. Results: Proton RBE values determined using the standard clonogenic assay at 90 %, 50 % and 10 % of cell survival were calculated to be 1.3, 1.5 and 1.6, respectively. This was found to be consistent with the RBE determined using the γ-H2AX for double-strand DNA break repair (1.58 for 10 % cell survival). In addition, we also observed that the high spatial resolution of the cassette can distinguish the minute but significant γ-H2AX foci changes (number, area) in response to small differences in proton radiation dose fraction. Significance: The results validate the reliability of the 3D printed cassette in addressing critical radiobiological issues. This methodology enables high throughput irradiation workflow and consequently reduce the time and resource burden for clinical facilities. This approach could be readily extended to investigate the radiobiological unknown of other emerging radiation therapy modalities based on charged particles.

Original languageEnglish
Article number344027
Pages (from-to)344027
JournalAnalytica Chimica Acta
Volume1356
DOIs
StatePublished - 22 06 2025

Bibliographical note

Copyright © 2025 The Authors. Published by Elsevier B.V. All rights reserved.

Keywords

  • 3D printing
  • Clonogenic assay
  • High throughput
  • Radiobiology
  • Relative biological effectiveness
  • Protons
  • Humans
  • Cell Survival/radiation effects
  • Histones/metabolism
  • High-Throughput Screening Assays
  • Proton Therapy
  • Relative Biological Effectiveness
  • Printing, Three-Dimensional

Fingerprint

Dive into the research topics of '3D printed microtissue cassettes enabling high throughput proton radiobiological assays'. Together they form a unique fingerprint.

Cite this