Abstract
There have been a variety of constant on-time (COT) controllers for dc power converter applications reported in recent years [1]-[5]. In this paper, a novel adaptive quasi-constant on-time current-mode control scheme is proposed and implemented in buck converters. While preserving the advantages of the conventional COT current-mode converters, this scheme allows fast transient response to step-load that is a critical requirement of a computer load with smart management. A small-signal model of the proposed circuit is also developed. Experimental results are also provided. This scheme is well suited for the next-generation dc converters for power management central-processor-unit devices.
| Original language | English |
|---|---|
| Article number | 7762949 |
| Pages (from-to) | 8124-8133 |
| Number of pages | 10 |
| Journal | IEEE Transactions on Power Electronics |
| Volume | 32 |
| Issue number | 10 |
| DOIs | |
| State | Published - 10 2017 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2016 IEEE.
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Buck converter
- constant on-time current-mode (COTCM)
- describing function (DF)
- voltage regulators (VRs)