Skip to main navigation Skip to search Skip to main content

A portable biodevice to monitor salivary conductivity for the rapid assessment of fluid status

  • Chun Hao Chen
  • , Yen Pei Lu
  • , An Ting Lee
  • , Chun Wu Tung
  • , Yuan Hsiung Tsai
  • , Hsin Pei Tsay
  • , Chih Ting Lin*
  • , Jen Tsung Yang*
  • *Corresponding author for this work
  • Chang Gung Memorial Hospital
  • National Applied Research Laboratories Taiwan
  • Chang Gung University
  • National Taiwan University

Research output: Contribution to journalJournal Article peer-review

10 Scopus citations

Abstract

The evaluation of fluid status can save adults from life-threatening conditions, but the current methods are invasive or time-consuming. Therefore, we developed a portable device for measuring salivary conductivity. This prospective observational study enrolled 20 volunteers with no history of systemic diseases. Participants were observed for 13 h, including water restriction for 12 h followed by rehydration with 1000 mL water within 1 h. Serum and urine biomarkers for fluid status, thirst scales, and salivary conductivity were collected during dehydration and rehydration. No significant differences in age, body mass index, glycohemoglobin, and estimated glomerular filtration rate were noted between sexes. Salivary conductivity increased after water restriction and decreased after rehydration. Similarly, urine osmolality, urine specific gravity, thirst intensity scales, and body weight followed the same trend and were statistically significant. The angiotensin-converting enzyme and aldosterone levels showed the same trend, without reaching statistical significance. The red blood cell count and hemoglobin concentration also followed the same trend. Analyzing the receiver operating characteristic curves, the area under the curve was 0.707 (95% confidence interval 0.542–0.873, p = 0.025). Using the Youden index, the optimal cutoff determined as 2678.09 µs/cm (sensitivity: 90%, specificity: 55%). This biodevice effectively screened dehydration among healthy adults.

Original languageEnglish
Article number577
JournalJournal of Personalized Medicine
Volume11
Issue number6
DOIs
StatePublished - 06 2021
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.

Keywords

  • Fluid status
  • Portable biodevice
  • Salivary conductivity

Fingerprint

Dive into the research topics of 'A portable biodevice to monitor salivary conductivity for the rapid assessment of fluid status'. Together they form a unique fingerprint.

Cite this