TY - JOUR
T1 - An Ultra-sensitive Electrochemical Sensor for the Detection of Oxidative Stress Biomarker 3-Nitro-l-tyrosine in Human Blood Serum and Saliva Samples Based on Reduced Graphene Oxide Entrapped Zirconium (IV) Oxide
AU - Maheshwaran, Selvarasu
AU - Akilarasan, Muthumariappan
AU - Chen, Shen Ming
AU - Chen, Tse Wei
AU - Tamilalagan, Elayappan
AU - Tzu, Chang Yen
AU - Lou, Bih Show
N1 - Publisher Copyright:
© 2020 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.
PY - 2020/1/4
Y1 - 2020/1/4
N2 - A sonochemical assisted preparation of zirconium dioxide (ZrO2) sheathed reduced graphene oxide (ZrO2@rGO NCs) nanocomposites as the highly sensitive electrode material for the detection of oxidative stress biomarker 3-Nitro-l-tyrosine (3-NT) was reported. The formation of prepared ZrO2@rGO NCs and its surface morphology were scrutinized by the X-ray photoelectron spectroscopy (XPS) and Field emission scanning electron microscope (FE-SEM). Moreover, the as-prepared nanocomposites were fabricated on the glassy carbon electrode (GCE), and its electrochemical performance towards the detection of 3-NT are studied by the various electrochemical techniques such as Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and amperometric (i-t). The excellent conductivity of the rGO and the electrocatalytic properties of the ZrO2 significantly improves the electrochemical performances. As a result, the ZrO2@rGO NCs display the LOD of 9 nM with the covering range of 0.025 to 855.2 μM towards the detection of 3-NT. Finally, the real-time practicability of ZrO2@rGO NCs in the spiked human serum and saliva samples also investigated, which shows the feasible found and recoveries. Hence, this study sonochemically prepared ZrO2@rGO NCs provides the simple, rapid and efficient towards the detection of 3-NT in biological samples.
AB - A sonochemical assisted preparation of zirconium dioxide (ZrO2) sheathed reduced graphene oxide (ZrO2@rGO NCs) nanocomposites as the highly sensitive electrode material for the detection of oxidative stress biomarker 3-Nitro-l-tyrosine (3-NT) was reported. The formation of prepared ZrO2@rGO NCs and its surface morphology were scrutinized by the X-ray photoelectron spectroscopy (XPS) and Field emission scanning electron microscope (FE-SEM). Moreover, the as-prepared nanocomposites were fabricated on the glassy carbon electrode (GCE), and its electrochemical performance towards the detection of 3-NT are studied by the various electrochemical techniques such as Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and amperometric (i-t). The excellent conductivity of the rGO and the electrocatalytic properties of the ZrO2 significantly improves the electrochemical performances. As a result, the ZrO2@rGO NCs display the LOD of 9 nM with the covering range of 0.025 to 855.2 μM towards the detection of 3-NT. Finally, the real-time practicability of ZrO2@rGO NCs in the spiked human serum and saliva samples also investigated, which shows the feasible found and recoveries. Hence, this study sonochemically prepared ZrO2@rGO NCs provides the simple, rapid and efficient towards the detection of 3-NT in biological samples.
UR - http://www.scopus.com/inward/record.url?scp=85084680722&partnerID=8YFLogxK
U2 - 10.1149/1945-7111/ab847d
DO - 10.1149/1945-7111/ab847d
M3 - 文章
AN - SCOPUS:85084680722
SN - 0013-4651
VL - 167
JO - Journal of the Electrochemical Society
JF - Journal of the Electrochemical Society
IS - 6
M1 - 066517
ER -