Application of Bispectral Index System (BIS) Monitor to Ambulatory Pediatric Dental Patients under Intravenous Deep Sedation

Shih Chia Chen, Chun Yu Chen, Shih Jyun Shen, Yung Fong Tsai, Yu Chen Ko, Li Chuan Chuang, Jr Rung Lin, Hsin I. Tsai*

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

3 Scopus citations

Abstract

Purpose Intravenous sedation has been well accepted to allow dental restoration in uncooperative children while avoiding aspiration and laryngospasm; however, intravenous anesthetics such as propofol may lead to undesired effects such as respiratory depression and delayed recovery. The use of the bispectral index system (BIS), a monitoring system reflective of the hypnotic state, is con-troversial in the reduction in the risk of respiratory adverse events (RAEs), recovery time, the in-travenous drug dosage, and post-procedural events. The aim of the study is to evaluate whether BIS is advantageous in pediatric dental procedures. Methods A total of 206 cases, aged 2–8 years, receiving dental procedures under deep sedation with propofol using target-controlled infusion (TCI) technique were enrolled in the study. BIS level was not monitored in 93 children whereas it was for 113 children, among which BIS values were maintained between 50–65. Physiological variables and adverse events were recorded. Statistical analysis was conducted using Chi-square, Mann Whitney U, Independent Samples t and Wilcoxon signed tests, with a p value of <0.05 considered to be statistically significant. Results Although no statistical significance in the post-discharge events and total amount of propofol used was observed, a clear significance was identified in periprocedural adverse events (hypoxia, apnea, and recurrent cough, all p value < 0.05) and discharge time (63.4 ± 23.2 vs. 74.5 ± 24.0 min, p value < 0.001) between these two groups. Conclusions The application of BIS in combination with TCI may be beneficial for young children undergoing deep sedation for dental procedures.

Original languageEnglish
Article number1789
JournalDiagnostics
Volume13
Issue number10
DOIs
StatePublished - 18 05 2023
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2023 by the authors.

Keywords

  • anesthesia
  • anesthesia recovery period
  • consciousness monitors
  • intravenous
  • pediatric dentistry
  • sedation

Fingerprint

Dive into the research topics of 'Application of Bispectral Index System (BIS) Monitor to Ambulatory Pediatric Dental Patients under Intravenous Deep Sedation'. Together they form a unique fingerprint.

Cite this