Artifact reduction of ultrasound nakagami imaging by combining multifocus image reconstruction and the noise-assisted correlation algorithm

Po Hsiang Tsui*, Yu Wei Tsai

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

21 Scopus citations

Abstract

Several studies have investigated Nakagami imaging to complement the B-scan in tissue characterization. The noise-induced artifact and the parameter ambiguity effect can affect performance of Nakagami imaging in the detection of variations in scatterer concentration. This study combined multifocus image reconstruction and the noise-assisted correlation algorithm (NCA) into the algorithm of Nakagami imaging to suppress the artifacts. A single-element imaging system equipped with a 5 MHz transducer was used to perform the brightness/depth (B/D) scanning of agar phantoms with scatterer concentrations ranging from 2 to 32 scatterers/mm3. Experiments were also carried out on a mass with some strong point reflectors in a breast phantom using a commercial scanner with a 7.5 MHz linear array transducer operated at multifocus mode. The multifocus radiofrequency (RF) signals after the NCA process were used for Nakagami imaging. In the experiments on agar phantoms, an increasing scatterer concentration from 2 to 32 scatterers/mm3 led to backscattered statistics ranging from pre-Rayleigh to Rayleigh distributions, corresponding to the increase in the Nakagami parameter measured in the focal zone from 0.1 to 0.8. However, the artifacts in the far field resulted in the Nakagami parameters of various scatterer concentrations to be close to 1 (Rayleigh distribution), making Nakagami imaging difficult to characterize scatterers. In the same scatterer concentration range, multifocus Nakagami imaging with the NCA simultaneously suppressed two types of artifacts, making the Nakagami parameter increase from 0.1 to 0.8 in the focal zone and from 0.18 to 0.7 in the far field, respectively. In the breast phantom experiments, the backscattered statistics of the mass corresponded to a high degree of pre-Rayleigh distribution. The Nakagami parameter of the mass before and after artifact reduction was 0.7 and 0.37, respectively. The results demonstrated that the proposed method for artifact reduction allows a sensitive and effective scatterer characterization by Nakagami imaging.

Original languageEnglish
Pages (from-to)53-69
Number of pages17
JournalUltrasonic Imaging
Volume37
Issue number1
DOIs
StatePublished - 03 01 2015

Bibliographical note

Publisher Copyright:
© The Author(s) 2014.

Keywords

  • Nakagami image
  • artifact
  • backscattering
  • envelope statistics
  • tissue characterization