Skip to main navigation Skip to search Skip to main content

Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - Retrospective cohort study

  • Po Ju Lai
  • , Yung Heng Hsu
  • , Ying Chao Chou
  • , Wen Ling Yeh
  • , Steve W.N. Ueng*
  • , Yi Hsun Yu
  • *Corresponding author for this work
  • Chang Gung University

Research output: Contribution to journalJournal Article peer-review

32 Scopus citations

Abstract

Background: Atrophic nonunion of femoral shaft fracture after intramedullary (IM) nailing is uncommon. The treatment for femoral shaft aseptic atrophic non-union remained controversial. The aim of this study was to compare the surgical results between exchanging reamed nailing (ERN) and augmentative antirotational plating (AAP) for femoral shaft aseptic atrophic nonunion. Methods: We retrospectively reviewed the patients with femoral shaft nonunion between the year of 2014 and 2015. The patients with nonunion after plate osteosynthesis, septic nonunion, hypertrophic nonunion, additional surgery during revision surgery were excluded. All the patients were followed up at least 12 months. Results: Overall, the union rate after revision surgery was 70.8%. The union rate was significantly higher in the AAP group than in the ERN group. Operating time was also significantly shorter in the AAP group. Regarding the location of nonunion, the union rate was comparable between groups for isthmic nonunions. However, for non-isthmic nonunions, the union rate was significantly higher and operating time was significantly shorter in the AAP group. Conclusion: AAP showed an overall higher union rate for management of femoral shaft aseptic atrophic nonunion compared with ERN. Especially for non-isthmic femoral shaft atrophic nonunions, AAP provided a significantly higher union rate and significantly shorter operating time.

Original languageEnglish
Article number127
JournalBMC Musculoskeletal Disorders
Volume20
Issue number1
DOIs
StatePublished - 25 03 2019

Bibliographical note

Publisher Copyright:
© 2019 The Author(s).

Keywords

  • Augmentative plate
  • Exchanging reamed nail
  • Nonunion femoral shaft fracture

Fingerprint

Dive into the research topics of 'Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - Retrospective cohort study'. Together they form a unique fingerprint.

Cite this