Abstract
In this paper, the average current method is proposed to detect the open-winding fault of three-phase permanent magnet synchronous motors (PMSMs). The characteristics and operational regions are studied. All the methods are implemented in FPGA-based system. The simulation and experimental results are provided to demonstrate the proposed method.
| Original language | English |
|---|---|
| Title of host publication | 2016 18th European Conference on Power Electronics and Applications, EPE 2016 ECCE Europe |
| Publisher | Institute of Electrical and Electronics Engineers Inc. |
| ISBN (Electronic) | 9789075815245 |
| DOIs | |
| State | Published - 25 10 2016 |
| Event | 18th European Conference on Power Electronics and Applications, EPE 2016 ECCE Europe - Karlsruhe, Germany Duration: 05 09 2016 → 09 09 2016 |
Publication series
| Name | 2016 18th European Conference on Power Electronics and Applications, EPE 2016 ECCE Europe |
|---|
Conference
| Conference | 18th European Conference on Power Electronics and Applications, EPE 2016 ECCE Europe |
|---|---|
| Country/Territory | Germany |
| City | Karlsruhe |
| Period | 05/09/16 → 09/09/16 |
Bibliographical note
Publisher Copyright:© 2016 IEEE and EPE Association.
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Open-Winding Fault
- Permanent-Magnet Synchronous Motor
Fingerprint
Dive into the research topics of 'Average current method to detect open-winding fault of three-phase permanent magnet synchronous motors'. Together they form a unique fingerprint.Cite this