Biomechanical comparison of different combinations of hook and screw in one spine motion unit - An experiment in porcine model

Research output: Contribution to journalJournal Article peer-review

15 Scopus citations

Abstract

Background: The biomechanical performance of the hooks and screws in spinal posterior instrumentation is not well-characterized. Screw-bone interface failure at the uppermost and lowermost vertebrae is not uncommon. Some have advocated for the use of supplement hooks to prevent screw loosening. However, studies describing methods for combined hook and screw systems that fully address the benefits of these systems are lacking. Thus, the choice of which implant to use in a given case is often based solely on a surgeon's experience instead of on the biomechanical features and advantages of each device. Methods. We conducted a biomechanical comparison of devices instrumented with different combinations of hooks and screws. Thirty-six fresh low thoracic porcine spines were assigned to three groups (12 per group) according to the configuration used for of fixation: (1) pedicle screw; (2) lamina hook and (3) combination of pedicle screw and lamina hook. Axial pullout tests backward on transverse plane in the direction normal to the rods were performed using a material testing machine and a specially designed grip with self-aligned function. Results: The pullout force for the pedicle screws group was significantly greater than for the hooks and the combination (p < 0.05). However, no significant difference was found between the hooks and the combination (p > 0.05). Conclusions: Pedicle screws achieve the maximal pullout strength for spinal posterior instrumentation.

Original languageEnglish
Article number197
JournalBMC Musculoskeletal Disorders
Volume15
Issue number1
DOIs
StatePublished - 09 06 2014

Keywords

  • Biomechanical study
  • Lamina hook
  • Pedicle screw
  • Porcine model

Fingerprint

Dive into the research topics of 'Biomechanical comparison of different combinations of hook and screw in one spine motion unit - An experiment in porcine model'. Together they form a unique fingerprint.

Cite this