Biomechanical comparison of three stand-alone lumbar cages - A three-dimensional finite element analysis

Shih Hao Chen, Ming Chieh Chiang, Jin Fu Lin, Shang Chih Lin, Ching Hua Hung*

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

20 Scopus citations

Abstract

Background: For anterior lumbar interbody fusion (ALIF), stand-alone cages can be supplemented with vertebral plate, locking screws, or threaded cylinder to avoid the use of posterior fixation. Intuitively, the plate, screw, and cylinder aim to be embedded into the vertebral bodies to effectively immobilize the cage itself. The kinematic and mechanical effects of these integrated components on the lumbar construct have not been extensively studied. A nonlinearly lumbar finite-element model was developed and validated to investigate the biomechanical differences between three stand-alone (Latero, SynFix, and Stabilis) and SynCage-Open plus transpedicular fixation. All four cages were instrumented at the L3-4 level. Methods. The lumbar models were subjected to the follower load along the lumbar column and the moment at the lumbar top to produce flexion (FL), extension (EX), left/right lateral bending (LLB, RLB), and left/right axial rotation (LAR, RAR). A 10 Nm moment was applied to obtain the six physiological motions in all models. The comparison indices included disc range of motion (ROM), facet contact force, and stresses of the annulus and implants. Results: At the surgical level, the SynCage-open model supplemented with transpedicular fixation decreased ROM (>76%) greatly; while the SynFix model decreased ROM 56-72%, the Latero model decreased ROM 36-91%, in all motions as compared with the INT model. However, the Stabilis model decreased ROM slightly in extension (11%), lateral bending (21%), and axial rotation (34%). At the adjacent levels, there were no obvious differences in ROM and annulus stress among all instrumented models. Conclusions: ALIF instrumentation with the Latero or SynFix cage provides an acceptable stability for clinical use without the requirement of additional posterior fixation. However, the Stabilis cage is not favored in extension and lateral bending because of insufficient stabilization.

Original languageEnglish
Article number281
JournalBMC Musculoskeletal Disorders
Volume14
DOIs
StatePublished - 2013
Externally publishedYes

Keywords

  • ALIF
  • Anterior lumbar interbody fusion
  • Finite element analysis
  • Stand-alone cage

Fingerprint

Dive into the research topics of 'Biomechanical comparison of three stand-alone lumbar cages - A three-dimensional finite element analysis'. Together they form a unique fingerprint.

Cite this