Abstract
Widespread spinal metastases can obscure bone landmarks and severely hinder surgical safety during pedicle screw insertion. Robot-assisted spinal surgery has demonstrated an excellent safety profile for pedicle screw insertion. Moreover, spinal surgery robotic systems can facilitate pedicle screw insertion with high-accuracy. We present a patient who had breast cancer with widespread spinal metastases, pathological vertebral fracture, and spinal cord compression with a challenge of intraoperative image recognition. To overcome this problem, she received surgical decompression and stabilization through the insertion of cement-augmented pedicle screws with the assistance of a spinal robotic system. At the 1-year follow-up, no implant loosening was observed, and the patient exhibited notable physical improvements, demonstrating that cement-augmented pedicle screw insertion with the assistance of spinal robotic systems is an effective method for treating widespread spinal metastases.
| Original language | English |
|---|---|
| Pages (from-to) | 595-598 |
| Number of pages | 4 |
| Journal | Journal of Robotic Surgery |
| Volume | 13 |
| Issue number | 4 |
| DOIs | |
| State | Published - 01 08 2019 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2018, Springer-Verlag London Ltd., part of Springer Nature.
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Cement augmentation
- Navigation
- Pedicle screw
- Robotic
- Spine metastases
Fingerprint
Dive into the research topics of 'Cement-augmented pedicle screw insertion assisted by spinal robotic systems for widespread spinal metastases'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver