Comparison of 9-month angiographic follow-up and long-term clinical outcomes of biodegradable polymer drug-eluting stents and second-generation durable polymer drug-eluting stents in patients undergoing single coronary artery stenting

Ming Lung Tsai, Ming Jer Hsieh, Chun Chi Chen, Shang Hung Chang, Chao Yung Wang, Dong Yi Chen, Chia Hung Yang, Jih Kai Yeh, Ming Yun Ho, I. Chang Hsieh*

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

10 Scopus citations

Abstract

Background: The durable polymers (DP) used in first-generation drug-eluting stents (DESs) were associated with long-term cardiovascular events, and thus biodegradable polymer DESs (BP-DESs) and second-generation DP-DESs were designed to overcome this problem. In this study, we compared angiographic follow-up and long-term clinical outcomes between patients who received BP-DESs or second-generation DP-DESs. Method: We enrolled 436 patients with single coronary lesions who received a second-generation DP-DES or BP-DES between June 2009 and October 2012. All patients received follow-up angiography when new clinical events developed or at 9 months after index stenting. All participants received follow-up for 5 years. Result: There were no significant differences in patient and lesion characteristics between the two groups. The 9-month angiographic follow-up showed a lower net gain in the second-generation DP-DES group (2.19 mm vs. 2.41 mm, p = 0.040), but a similar binary restenosis rate between the two groups (5.4% vs. 8.7%, p = 0.276). During the 5-year follow-up period, no significant differences were observed between the two groups in major adverse cardiac events (MACEs), cardiovascular death, nonfatal myocardial infarction (MI), target vessel revascularization (TVR), all revascularization, stent thrombosis (ST), or MACE-free survival. Conclusions: No significant differences were observed in cardiovascular death, nonfatal MI, TVR, all revascularization, ST, or MACE-free survival between the patients undergoing single coronary artery stenting with BP-DESs and second-generation DP-DESs.

Original languageEnglish
Pages (from-to)97-104
Number of pages8
JournalActa Cardiologica Sinica
Volume36
Issue number2
DOIs
StatePublished - 03 2020

Bibliographical note

Publisher Copyright:
© 2020, Republic of China Society of Cardiology. All rights reserved.

Keywords

  • Coronary artery disease
  • Drug-eluting stent
  • Major adverse cardiac events
  • Polymer

Fingerprint

Dive into the research topics of 'Comparison of 9-month angiographic follow-up and long-term clinical outcomes of biodegradable polymer drug-eluting stents and second-generation durable polymer drug-eluting stents in patients undergoing single coronary artery stenting'. Together they form a unique fingerprint.

Cite this