Skip to main navigation Skip to search Skip to main content

Comparison of two detector systems for cone beam CT small animal imaging - A preliminary study

  • Yang Meng*
  • , Chris C. Shaw
  • , Xinming Liu
  • , Mustafa C. Altunbas
  • , Tianpeng Wang
  • , Lingyun Chen
  • , Shu Ju Tu
  • , S. Cheenu Kappadath
  • , Chao Jen Lai
  • *Corresponding author for this work
  • University of Texas Health Science Center at Houston

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

4 Scopus citations

Abstract

Purpose: To compare two detector systems - one based on the charge-coupled device (CCD) and image amplifier, the other based on a-Si/CsI flat panel, for cone beam computed-tomography (CT) imaging of small animals. A high resolution, high framing rate detector system for the cone beam CT imaging of small animals was developed. The system consists of a 2048×3072×12 bit CCD optically coupled to an image amplifier and an x-ray phosphor screen. The CCD has an intrinsic pixel size of 12 μm but the effective pixel size can be adjusted through the magnification adjustment of the optical coupling systems. The system is used in conjunction with an x-ray source and a rotating stage for holding and rotating the scanned object in the cone beam CT imaging experiments. The advantages of the system include but are not limited to the ability to adjust the effective pixel size and to achieve extremely high spatial resolution and temporal resolution. However, the need to use optical coupling compromises the detective quanta efficiency (DQE) of the system. In this paper, the imaging characteristics of the system were presented and compared with those of an a-Si/CsI flat-panel detector system.

Original languageEnglish
Title of host publicationMedical Imaging 2006
Subtitle of host publicationPhysics of Medical Imaging
DOIs
StatePublished - 2006
Externally publishedYes
EventMedical Imaging 2006: Physics of Medical Imaging - San Diego, CA, United States
Duration: 12 02 200616 02 2006

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6142 III
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2006: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period12/02/0616/02/06

Keywords

  • CCD
  • Cone beam CT
  • Flat panel
  • Small animal imaging

Fingerprint

Dive into the research topics of 'Comparison of two detector systems for cone beam CT small animal imaging - A preliminary study'. Together they form a unique fingerprint.