Comparison of using Galilei Dual Scheimpflug Analyzer G4 and Barrett formula in predicting low cylinder preoperatively for cataract surgeries

Yi Ju Ho, Chi Chin Sun, Jiahn Shing Lee, Ken Kuo Lin, Chiun Ho Hou*

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

3 Scopus citations

Abstract

Purpose: To compare corneal astigmatism estimation from Barrett toric calculator, with measurement from Galilei Dual Scheimpflug Analyzer G4 in low corneal cylinder patients. Methods: Preoperative corneal astigmatism was measured using Auto Kerato-Refractometer (AutoKM), IOL Master, and Galilei G4 (combined Placido-dual Scheimpflug analyzer) and was processed by Barrett toric calculator with measurements obtained from Auto Kerato-Refractometer and from IOL Master. A total of 42 eyes undergoing cataract surgery with nontoric intraocular lens implantation were included. Corneal astigmatism was calculated based on manifest refractive astigmatism with implications of surgically induced astigmatism. Errors in predicted residual astigmatism were calculated by the difference between postoperative manifest cylindrical refractive error and preoperative corneal cylinder using vector analysis. Results: Centroid error in predicted residual astigmatism was with-the-rule 0.36 D for AutoKM and 0.48 D for IOL Master, was lower at 0.24 D for the Barrett–IOL Master, and was lowest at 0.21 D for the Barrett–AutoKM (p <.001). The Galilei G4 demonstrated the highest centroid error for SimK (0.53 D) and lower for total corneal power (0.49 D). The Barrett toric calculator obtained the lowest median absolute error in predicted residual astigmatism for AutoKM (0.43 D) and IOL Master (0.54 D). The Barrett–IOL Master demonstrated that 61% and 76% of eyes were within 0.50 and 0.75 D of the predicted residual astigmatism, respectively. Conclusion: The Barrett–IOL Master had more accurate prediction of residual astigmatism for low astigmatism eyes before cataract surgery compared to Galilei Dual Scheimpflug Analyzer G4 in this study.

Original languageEnglish
Pages (from-to)1320-1327
Number of pages8
JournalEuropean Journal of Ophthalmology
Volume30
Issue number6
DOIs
StatePublished - 11 2020

Bibliographical note

Publisher Copyright:
© The Author(s) 2019.

Keywords

  • Astigmatism
  • Barrett
  • Galilei
  • intraocular lens
  • toric

Fingerprint

Dive into the research topics of 'Comparison of using Galilei Dual Scheimpflug Analyzer G4 and Barrett formula in predicting low cylinder preoperatively for cataract surgeries'. Together they form a unique fingerprint.

Cite this