Abstract

This study developed a magnetic particle imaging (MPI) system for detecting tumors following the injection of biofunctional magnetic nanoparticles (BMNs) into mouse tumors. To enhance system sensitivity, a gradiometer composed of reverse-series pick-up coils connected to an input coil, which is coupled to a high-Tc superconducting quantum interference device (SQUID), was incorporated. The system employed a three-dimensional stepper motor to scan the tumor region by moving the mice, thereby obtaining the magnetic distribution image. Third harmonic signals from the specimen were detected to minimize interference from biological diamagnetic signals. Furthermore, a flux coupling technique was applied to prevent the fundamental frequency excitation field from affecting SQUID sensitivity. To distinguish the magnetic signal between the magnetic specimen and positioning points, four positioning coils operating at a different frequency were used. The distinct response frequencies enabled offline signal separation between the positioning coils and BMNs within the mice. Subsequently, the magnetic field map of specimen inside mice and its reconstructed distribution were obtained. After the co-registration between MPI and magnetic resonance imaging (MRI), an integrated image was generated, providing a source-estimated visualization. Finally, early diagnosis of mouse tumors was performed to verify the feasibility and high sensitivity of MPI detection.

Original languageEnglish
Article number118015
JournalSensors and Actuators, A: Physical
Volume408
DOIs
StatePublished - 01 10 2026
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2026 Elsevier B.V. All rights are reserved, including those for text and data mining, AI training, and similar technologies.

Keywords

  • Biomagnetic Imaging
  • High-Tc SQUID
  • Magnetic Particle Imaging (MPI)
  • Third-Harmonic Detection
  • Tumor Detection

Fingerprint

Dive into the research topics of 'Construction and characterization of a high-Tc SQUID-based biomagnetic particle imaging system with MRI co-registration via third-harmonic detection in animal models'. Together they form a unique fingerprint.

Cite this