Dynamic perfusion assessment by contrast-enhanced ultrasound in blood-brain barrier disruption

  • Wun Hao Lin
  • , Ching Hsiang Fan
  • , Chien Yu Ting
  • , Hao Li Liu
  • , Chih Kuang Yeh

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

9 Scopus citations

Abstract

Recently, blood-brain barrier disruption (BBBD) has been performed by focused ultrasound (FUS) combining with microbubbles (MBs). The outcome of BBBD enhances local drug or gene delivery for improving the treatment efficiency of brain diseases. However, over-excitation of FUS may cause brain damage such as shutdown blood flow, intracerebral hemorrhage and brain edema. Therefore, it is essential to develop a an imaging system to assess dynamic perfusion changes during FUS-induced BBBD process. Here, we used the high-frequency destruction/reperfusion contrast-enhanced imaging technique to observe the cerebral perfusion under the cases of with/without hemorrhage in BBBD procedure. The BBB was disrupted by a 2.25 MHz FUS combining with MBs at 0.5-0.7 MPa (pulse repetition frequency: 1 Hz, pulse length: 1 ms, sonication time: 60 s). The results showed that the velocity of blood flow decreased after BBBD induced by FUS sonication. Particularly, the plateau of time-intensity curve was higher than prior to MBs destruction at 20 s after sonication and the blood flow would be obstructed due to the blood coagulates at 60s after sonication. The pattern of hemorrhagic damage caused by FUS can be monitored by the TIC. In addition, the location of blood flow velocity decrease was consistent with the areas of BBBD and the variation of blood flow depends on the applied acoustic pressure. In conclusion, the blood flow velocity changes have potential as an in vivo tool for quantifying the extent of the FUS-induced BBBD and detecting intracerebral hemorrhage occurrence.

Original languageEnglish
Title of host publication2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Pages1152-1155
Number of pages4
DOIs
StatePublished - 2013
Event2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013 - Osaka, Japan
Duration: 03 07 201307 07 2013

Publication series

NameProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
ISSN (Print)1557-170X

Conference

Conference2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Country/TerritoryJapan
CityOsaka
Period03/07/1307/07/13

Keywords

  • Blood-brain barrier
  • destruction/reperfusion
  • focused ultrasound
  • microbubbles

Fingerprint

Dive into the research topics of 'Dynamic perfusion assessment by contrast-enhanced ultrasound in blood-brain barrier disruption'. Together they form a unique fingerprint.

Cite this