Effect of chlorination bulking control on water quality and phosphate release/uptake in an anaerobic-oxic activated sludge system

W. C. Chang*, S. J. Jou, C. C. Chien, J. A. He

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

6 Scopus citations

Abstract

This study evaluates the effect of chlorination bulking control on water quality and phosphate release/uptake in an anaerobic-oxic activated sludge system. A series of batch experiments with different specific NaOCI mass dose were conducted to determine the sludge settling properties, supernatant water quality and phosphate metabolism behavior of filamentous bulking sludge. The harvested sludge was from a continuous-flow anaerobic-oxic (A/O) activated sludge pilot-plant, i.e., enhanced biological phosphorus removal (EBPR) system, operated with 15 days of sludge retention time. The filamentous bacteria in the A/O pilot plant were identified to be Thiothrix according to Eikelboom's classification techniques, which was in accordance with the high influent sulfate concentration of this study (50 mg/L sulfate). Increasing NaOCI concentration, as revealed by experimental results, obviously decreased the sludge settling properties (SVI values and zone settling velocities) and meanwhile significantly reduced supernatant water quality (COD, SS, TP) mainly due to higher suspended solids caused by floc disruption. Moreover, the nine-hour batch experiments indicated that high NaOCI dosage (40 mg/gMLSS) completely deteriorated phosphate metabolism of EBPR sludge. Such a high dosage of chlorination further confirmed overdosing through disappearance of intracellular PHB and death of protozoa by microscopic investigation. Still, phosphate release/uptake behavior of EBPR sludge properly functions at low NaOCI dosage (5 mg/g MLSS). Besides, phosphate metabolism worsens rapidly before the SVI value reaches its lowest level. These findings imply that determining NaOCI requirement with merely SVI values can readily result in chlorination overdosing. Proper NaOCI dosage requires a delicately balanced consideration between sludge settling improvement, water quality demand and phosphate metabolism. Batch test of phosphate release/uptake is apparently a prerequisite to conclude an appropriate NaOCI dosage for bulking control.

Original languageEnglish
Pages (from-to)177-183
Number of pages7
JournalWater Science and Technology
Volume50
Issue number8
DOIs
StatePublished - 2004
Externally publishedYes

Keywords

  • Anaerobic-oxic activated sludge process
  • Bulking control
  • Chlorination
  • Phosphate release
  • Phosphate uptake

Fingerprint

Dive into the research topics of 'Effect of chlorination bulking control on water quality and phosphate release/uptake in an anaerobic-oxic activated sludge system'. Together they form a unique fingerprint.

Cite this