Effect of ultrasound frequency on the Nakagami statistics of human liver tissues

Po Hsiang Tsui*, Zhuhuang Zhou, Ying Hsiu Lin, Chieh Ming Hung, Shih Jou Chung, Yung Liang Wan

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

37 Scopus citations

Abstract

The analysis of the backscattered statistics using the Nakagami parameter is an emerging ultrasound technique for assessing hepatic steatosis and fibrosis. Previous studies indicated that the echo amplitude distribution of a normal liver follows the Rayleigh distribution (the Nakagami parameter m is close to 1). However, using different frequencies may change the backscattered statistics of normal livers. This study explored the frequency dependence of the backscattered statistics in human livers and then discussed the sources of ultrasound scattering in the liver. A total of 30 healthy participants were enrolled to undergo a standard care ultrasound examination on the liver, which is a natural model containing diffuse and coherent scatterers. The liver of each volunteer was scanned from the right intercostal view to obtain image raw data at different central frequencies ranging from 2 to 3.5 MHz. Phantoms with diffuse scatterers only were also made to perform ultrasound scanning using the same protocol for comparisons with clinical data. The Nakagami parameter–frequency correlation was evaluated using Pearson correlation analysis. The median and interquartile range of the Nakagami parameter obtained from livers was 1.00 (0.98–1.05) for 2 MHz, 0.93 (0.89–0.98) for 2.3 MHz, 0.87 (0.84–0.92) for 2.5 MHz, 0.82 (0.77–0.88) for 3.3 MHz, and 0.81 (0.76–0.88) for 3.5 MHz. The Nakagami parameter decreased with the increasing central frequency (r = −0.67, p < 0.0001). However, the effect of ultrasound frequency on the statistical distribution of the backscattered envelopes was not found in the phantom results (r = −0.147, p = 0.0727). The current results demonstrated that the backscattered statistics of normal livers is frequency-dependent. Moreover, the coherent scatterers may be the primary factor to dominate the frequency dependence of the backscattered statistics in a liver.

Original languageEnglish
Article numbere0181789
JournalPLoS ONE
Volume12
Issue number8
DOIs
StatePublished - 08 2017

Bibliographical note

Publisher Copyright:
© 2017 Tsui et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Keywords

  • ACOUSTIC STRUCTURE QUANTIFICATION
  • BACKSCATTERED STATISTICS
  • CHRONIC HEPATITIS-B
  • CIRRHOTIC LIVER
  • DISEASE
  • FIBROSIS
  • HOMODYNED K-DISTRIBUTION
  • MAGNETIC-RESONANCE ELASTOGRAPHY
  • SPECTROSCOPY
  • STEATOSIS

Fingerprint

Dive into the research topics of 'Effect of ultrasound frequency on the Nakagami statistics of human liver tissues'. Together they form a unique fingerprint.

Cite this