Evaluation of an LYSO based multi-PMT detector for both positron and single photon imaging usage

H. C. Liang, M. L. Jan*, J. L. Su

*Corresponding author for this work

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Scopus citations

Abstract

In this research, Characteristics of combination of H8500 PSPMTs to form a larger detection area is studied. A home-made linear divider circuit was built for the merged Signals readout. Borosilicate glasses with several thicknesses (0-5 mm) were chosen for scintillation light sharing in crossover region. The effects of light guide and crossover region on separable crystal size were evaluated. According to the test results, an imaging gamma head with larger crystal block with 89 × 89 mm2 covered area, composed of 2 mm LYSO pixels, was fabricated and tested. Measured performances showed that this imaging head worked fine in both 511 keV and lower energy gamma rays. Through count rate measurements, the influence of 176Lu nature background for single photon imaging was also presented. These results showed that using light sharing and linear resistor chain techniques, combination of PMTs in X,Y directions to build a large area imaging detector is still able to keep the ability of positron and single photons detections. Separable crystal size was 2 mm with 2 mm glass applied for light sharing in current status.

Original languageEnglish
Title of host publication2006 IEEE Nuclear Science Symposium - Conference Record
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1896-1899
Number of pages4
ISBN (Print)1424405610, 9781424405619
DOIs
StatePublished - 2006
Externally publishedYes
Event2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD - San Diego, CA, United States
Duration: 29 10 200604 11 2006

Publication series

NameIEEE Nuclear Science Symposium Conference Record
Volume3
ISSN (Print)1095-7863

Conference

Conference2006 IEEE Nuclear Science Symposium, Medical Imaging Conference and 15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors, Special Focus Workshops, NSS/MIC/RTSD
Country/TerritoryUnited States
CitySan Diego, CA
Period29/10/0604/11/06