False aneurysm and mediastinal hematoma: complications of simultaneous transcatheter therapy for coarctation of the aorta and patent ductus arteriosus in an infant.

  • C. D. Liang*
  • , Sheung-fat Ko
  • , M. M. Tiao
  • *Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

7 Scopus citations

Abstract

We report an infant with intractable congestive heart failure caused by coarctation of the aorta, patent ductus arteriosus, atrial septal defect, and multiple muscular ventricular septal defects. He had received balloon angioplasty for dilating the aortic coarctation and a Gianturco coil for closing the ductus at a single therapeutic catheterization session at 4 months old. After balloon angioplasty, his heart failure had dramatically resolved. A false aneurysm and mediastinal hematoma were noted on the following day. The hematoma revealed total resolution 10 weeks later. He was asymptomatic throughout 12 months of follow-up.

Original languageEnglish
Pages (from-to)710-712
Number of pages3
JournalThe Journal of invasive cardiology
Volume13
Issue number10
StatePublished - 10 2001

Fingerprint

Dive into the research topics of 'False aneurysm and mediastinal hematoma: complications of simultaneous transcatheter therapy for coarctation of the aorta and patent ductus arteriosus in an infant.'. Together they form a unique fingerprint.