Finite element analysis of biomechanical interactions of a tooth-implant splinting system for various bone qualities

Chun Li Lin*, Shih Hao Chang, Jen Chyan Wang

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

14 Scopus citations

Abstract

Background: The splinting of an implant and tooth is a rational alternative in some clinical situations. The complex biomechanical aspects of a tooth-implant system are derived from the dissimilar mobility between the osseointegrated implant and the tooth. The aim of this study was to analyze the biomechanics in a tooth-implant splinting system for various bone qualities with different occlusal forces using non-linear finite element (FE) analysis. Methods: A 3D FE model containing one Frialit-2 implant splinted to the mandibular second premolar and a simplified bony segment was constructed. Four bone quality categories were established by varying the elastic parameters assigned to the bone volumes. Contact elements (frictional surface) were used to simulate the realistic frictional interface condition within the implant system. The stress distributions in the splinting system were observed for four loading types. Results: The simulated results indicated that the lateral occlusal forces significantly increased the implant system (σI, max), alveolar bone (σAB, max) and prosthesis (σP, max) stress values when compared with the axial occlusal forces. The σI, max and σP, max values did not exhibit significant differences between the four bone qualities. Conversely, the σAB, max values increased with reduction in bone quality, in particular for type IV bone quality. The σI, max, σAB, max and σP, max stress values were significantly reduced in centric or lateral contact situations once the occlusal forces on the pontic were decreased. Conclusions: This study suggests that implants connected to natural teeth should be used with caution in softer bone regions. Utilizing occlusal adjustment to minimize the occlusal loading force on the pontic could reduce the stress/strain values in the splinting system.

Original languageEnglish
Pages (from-to)143-153
Number of pages11
JournalChang Gung Medical Journal
Volume29
Issue number2
StatePublished - 03 2006

Keywords

  • Biomechanics
  • Bone quality
  • Finite element analysis
  • Tooth-implant splinting

Fingerprint

Dive into the research topics of 'Finite element analysis of biomechanical interactions of a tooth-implant splinting system for various bone qualities'. Together they form a unique fingerprint.

Cite this