Skip to main navigation Skip to search Skip to main content

Global Compressive Loading from an Ultra-Thin PEEK Button Augment Enhances Fibrocartilage Regeneration of Rotator Cuff Enthesis

  • Chia Wei Lin
  • , En Rung Chiang
  • , Shih Hao Chen
  • , Poyu Chen
  • , Heng Jui Liu
  • , Joe Chih Hao Chiu*
  • *Corresponding author for this work
  • Lin Shin Hospital
  • De Novo Orthopedics Inc
  • Veterans General Hospital-Taipei
  • National Yang Ming Chiao Tung University
  • Buddhist Tzu Chi Medical Foundation
  • Tzu Chi University
  • Chang Gung Memorial Hospital

Research output: Contribution to journal › Journal Article › peer-review

Abstract

A PEEK button is developed to improve the tendon-to-bone compression area. In total, 18 goats were divided into 12-week, 4-week, and 0-week groups. All underwent bilateral detachment of the infraspinatus tendon. In the 12-week group, 6 were fixed with a 0.8–1 mm-thick PEEK augment (A-12, Augmented), and 6 were fixed with the double-row technique (DR-12). Overall, 6 infraspinatus were fixed with PEEK augment (A-4) and without PEEK augment (DR-4) in the 4-week group. The same condition was performed in the 0-week groups (A-0 and DR-0). Mechanical testing, immunohistochemistry assessment, cell responses, tissue alternation, surgical impact, remodeling, and the expression of type I, II, and III collagen of the native tendon-to-bone insertion and new footprint areas were evaluated. The average maximum load in the A-12 group (393.75 (84.40) N) was significantly larger than in the TOE-12 group (229.17 (43.94) N) (p < 0.001). Cell responses and tissue alternations in the 4-week group were slight. The new footprint area of the A-4 group had better fibrocartilage maturation and more type III collagen expression than in DR-4 group. This result proved the novel device is safe and provides superior load-displacement to the double-row technique. There is a trend toward better fibrocartilage maturation and more collagen III secretions in the PEEK augmentation group.

Original languageEnglish
Article number565
JournalBioengineering
Volume10
Issue number5
DOIs
StatePublished - 09 05 2023

Bibliographical note

Publisher Copyright:
© 2023 by the authors.

Keywords

  • augmentation
  • double row
  • footprint compression
  • rotator cuff repair
  • transosseous equivalent

Fingerprint

Dive into the research topics of 'Global Compressive Loading from an Ultra-Thin PEEK Button Augment Enhances Fibrocartilage Regeneration of Rotator Cuff Enthesis'. Together they form a unique fingerprint.

Cite this