Abstract
The effects of current density and rotating speed on hard chromium plating on steel are studied using a rotating cylinder electrode (RCE) specimen. The chromium steel interfacial TEM microstructure is investigated using optical microscopy, scanning electron microscopy (SEM) and X-ray diffraction (XRD). The interfacial microstructure shows nanoscale grain sizes, although large size difference and textured structure still exist among grains in various regions.
| Original language | English |
|---|---|
| Pages (from-to) | 1357-1359 |
| Number of pages | 3 |
| Journal | Journal of Materials Science Letters |
| Volume | 19 |
| Issue number | 15 |
| DOIs | |
| State | Published - 08 2000 |
Fingerprint
Dive into the research topics of 'Hard chromium plating on cold swaged Cr-Mo steel using rotating cylinder electrode'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver