TY - JOUR
T1 - High-purity and label-free isolation of circulating tumor cells (CTCs) in a microfluidic platform by using optically-induced-dielectrophoretic (ODEP) force
AU - Huang, Song Bin
AU - Wu, Min Hsien
AU - Lin, Yen Heng
AU - Hsieh, Chia Hsun
AU - Yang, Chih Liang
AU - Lin, Hung Chih
AU - Tseng, Ching Ping
AU - Lee, Gwo Bin
PY - 2013/4/7
Y1 - 2013/4/7
N2 - Negative selection-based circulating tumor cell (CTC) isolation is believed valuable to harvest more native, and in particular all possible CTCs without biases relevant to the properties of surface antigens on the CTCs. Under such a cell isolation strategy, however, the CTC purity is normally compromised. To address this issue, this study reports the integration of optically-induced- dielectrophoretic (ODEP) force-based cell manipulation, and a laminar flow regime in a microfluidic platform for the isolation of untreated, and highly pure CTCs after conventional negative selection-based CTC isolation. In the design, six sections of moving light-bar screens were continuously and simultaneously exerted in two parallel laminar flows to concurrently separate the cancer cells from the leukocytes based on their size difference and electric properties. The separated cell populations were further partitioned, delivered, and collected through the two flows. With this approach, the cancer cells can be isolated in a continuous, effective, and efficient manner. In this study, the operating conditions of ODEP for the manipulation of prostate cancer (PC-3) and human oral cancer (OEC-M1) cells, and leukocytes with minor cell aggregation phenomenon were first characterized. Moreover, performances of the proposed method for the isolation of cancer cells were experimentally investigated. The results showed that the presented CTC isolation scheme was able to isolate PC-3 cells or OEC-M1 cells from a leukocyte background with high recovery rate (PC-3 cells: 76-83%, OEC-M1 cells: 61-68%), and high purity (PC-3 cells: 74-82%, OEC-M1 cells: 64-66%) (set flow rate: 0.1 μl min-1 and sample volume: 1 μl). The latter is beyond what is currently possible in the conventional CTC isolations. Moreover, the viability of isolated cancer cells was evaluated to be as high as 94 ± 2%, and 95 ± 3% for the PC-3, and OEC-M1 cells, respectively. Furthermore, the isolated cancer cells were also shown to preserve their proliferative capability. As a whole, this study has presented an ODEP-based microfluidic platform that is capable of isolating CTCs in a continuous, label-free, cell-friendly, and particularly highly pure manner. All these traits are found particularly meaningful for exploiting the harvested CTCs for the subsequent cell-based, or biochemical assays.
AB - Negative selection-based circulating tumor cell (CTC) isolation is believed valuable to harvest more native, and in particular all possible CTCs without biases relevant to the properties of surface antigens on the CTCs. Under such a cell isolation strategy, however, the CTC purity is normally compromised. To address this issue, this study reports the integration of optically-induced- dielectrophoretic (ODEP) force-based cell manipulation, and a laminar flow regime in a microfluidic platform for the isolation of untreated, and highly pure CTCs after conventional negative selection-based CTC isolation. In the design, six sections of moving light-bar screens were continuously and simultaneously exerted in two parallel laminar flows to concurrently separate the cancer cells from the leukocytes based on their size difference and electric properties. The separated cell populations were further partitioned, delivered, and collected through the two flows. With this approach, the cancer cells can be isolated in a continuous, effective, and efficient manner. In this study, the operating conditions of ODEP for the manipulation of prostate cancer (PC-3) and human oral cancer (OEC-M1) cells, and leukocytes with minor cell aggregation phenomenon were first characterized. Moreover, performances of the proposed method for the isolation of cancer cells were experimentally investigated. The results showed that the presented CTC isolation scheme was able to isolate PC-3 cells or OEC-M1 cells from a leukocyte background with high recovery rate (PC-3 cells: 76-83%, OEC-M1 cells: 61-68%), and high purity (PC-3 cells: 74-82%, OEC-M1 cells: 64-66%) (set flow rate: 0.1 μl min-1 and sample volume: 1 μl). The latter is beyond what is currently possible in the conventional CTC isolations. Moreover, the viability of isolated cancer cells was evaluated to be as high as 94 ± 2%, and 95 ± 3% for the PC-3, and OEC-M1 cells, respectively. Furthermore, the isolated cancer cells were also shown to preserve their proliferative capability. As a whole, this study has presented an ODEP-based microfluidic platform that is capable of isolating CTCs in a continuous, label-free, cell-friendly, and particularly highly pure manner. All these traits are found particularly meaningful for exploiting the harvested CTCs for the subsequent cell-based, or biochemical assays.
UR - https://www.scopus.com/pages/publications/84874829102
U2 - 10.1039/c3lc41256c
DO - 10.1039/c3lc41256c
M3 - 文章
AN - SCOPUS:84874829102
SN - 1473-0197
VL - 13
SP - 1371
EP - 1383
JO - Lab on a Chip
JF - Lab on a Chip
IS - 7
ER -