Skip to main navigation Skip to search Skip to main content

Human papillomavirus typing with a polymerase chain reaction-based genotyping array compared with type-specific PCR

  • Ching Yu Lin
  • , Angel Chao
  • , Yuh Cheng Yang
  • , Hung Hsueh Chou
  • , Chih Ming Ho
  • , Ruey Wen Lin
  • , Ting Chang Chang
  • , Jia Yia Chiou
  • , Fang Yu Chao
  • , Kung Liahng Wang
  • , Tsai Yen Chien
  • , Swei Hsueh
  • , Chu Chun Huang
  • , Chien Jen Chen
  • , Chyong Huey Lai*
  • *Corresponding author for this work
  • Taipei Medical University
  • King Car Food Industrial Co. Ltd.
  • Chang Gung Memorial Hospital
  • Mackay Memorial Hospital Taiwan
  • Cathay General Hospital Taiwan
  • Academia Sinica - Genomics Research Center
  • National Taiwan University

Research output: Contribution to journalJournal Article peer-review

38 Scopus citations

Abstract

Background: Type-specific persistence of human papillomavirus (HPV) infection can cause invasive cervical cancer. Objectives: To evaluate the efficacy of HPV detection and typing with a general polymerase chain reaction (PCR)-based genotyping array and to compare it with a type-specific PCR assay. Study design: Four hundred and thirty-three cervical samples were tested with a modified MY11/GP6+ PCR-based reverse-blot assay (EasyChip® HPV Blot; King Car, Taiwan [hereafter HPV Blot]) and with 20 genotypes of L1-type-specific PCR (HPV-6, -11, -16, -18, -31, -33, -35, -39, -45, -51, -52, -53, -56, -58, -59, -62, -66, -68, -70, and -71 [CP8061]). Results: The concordance of the two tests in determining HPV positivity was 96.8% (419/433), with a Cohen's κ = 0.93 (95% CI: 0.90-0.97) and McNemar's test of P = 1.0, which indicates excellent agreement. The overall concordance of the two tests in the identification of type-specific HPV was 91.0% (394/433). Sensitivity (90-100%), specificity (99.2-100%), and accuracy (98.6-100%) rates of HPV Blot against the gold standard were satisfactory for HPV-16, -18, -58, -33, -52, -39, -45, -31, -51, -70 while HPV-71 (63.6%) had suboptimal sensitivity. Though the κ values between the two tests for many individual genotypes could not be reliably calculated because of low positivity, the κ values for HPV-16, -52, and -58 were excellent (0.93, 0.96, and 0.95, respectively). Conclusion: The modified MY11/GP6+ PCR-based HPV Blot assay is accurate and sensitive for detection and genotyping of HPV in cervical swab samples.

Original languageEnglish
Pages (from-to)361-367
Number of pages7
JournalJournal of Clinical Virology
Volume42
Issue number4
DOIs
StatePublished - 08 2008
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Agreement
  • HPV Blot
  • Human papillomavirus
  • Type-specific PCR

Fingerprint

Dive into the research topics of 'Human papillomavirus typing with a polymerase chain reaction-based genotyping array compared with type-specific PCR'. Together they form a unique fingerprint.

Cite this