TY - JOUR
T1 - Improvement of surge protection by using an AlGaN/GaN-based metal-semiconductor-metal two-dimensional electron gas varactor
AU - Ferng, Yi Cherng
AU - Chang, Liann Be
AU - Das, Atanu
AU - Lin, Ching Chi
AU - Cheng, Chun Yu
AU - Kuei, Ping Yu
AU - Chow, Lee
PY - 2012/12
Y1 - 2012/12
N2 - In this paper, a varactor with metal-semiconductor-metal diodes on top of the (NH4)2S/P2S5-treated AlGaN/GaN two-dimensional electron gas epitaxial structure (MSM-2DEG) is proposed to the surge protection for the first time. The sulfur-treated MSM-2DEG varactor properties, including current-voltage (I-V), capacitance-voltage (C-V), and frequency response of the proposed surge protection circuit, are presented. To verify its capability of surge protection, we replace the metal oxide varistor (MOV) and resistor (R) in a state-of-the-art surge protection circuit with the sulfur-treated MSM-2DEG varactor under the application conditions of system-level surge tests. The measured results show that the proposed surge protection circuit, consisted of a gas discharge arrester (GDA) and a sulfur-treated MSM-2DEG varactor, can suppress an electromagnetic pulse (EMP) voltage of 4000 to 360 V, a reduction of 91%, whereas suppression is to 1780 V, a reduction of 55%, when using only a GDA.
AB - In this paper, a varactor with metal-semiconductor-metal diodes on top of the (NH4)2S/P2S5-treated AlGaN/GaN two-dimensional electron gas epitaxial structure (MSM-2DEG) is proposed to the surge protection for the first time. The sulfur-treated MSM-2DEG varactor properties, including current-voltage (I-V), capacitance-voltage (C-V), and frequency response of the proposed surge protection circuit, are presented. To verify its capability of surge protection, we replace the metal oxide varistor (MOV) and resistor (R) in a state-of-the-art surge protection circuit with the sulfur-treated MSM-2DEG varactor under the application conditions of system-level surge tests. The measured results show that the proposed surge protection circuit, consisted of a gas discharge arrester (GDA) and a sulfur-treated MSM-2DEG varactor, can suppress an electromagnetic pulse (EMP) voltage of 4000 to 360 V, a reduction of 91%, whereas suppression is to 1780 V, a reduction of 55%, when using only a GDA.
UR - https://www.scopus.com/pages/publications/84872507689
U2 - 10.1143/JJAP.51.124201
DO - 10.1143/JJAP.51.124201
M3 - 文章
AN - SCOPUS:84872507689
SN - 0021-4922
VL - 51
JO - Japanese Journal of Applied Physics
JF - Japanese Journal of Applied Physics
IS - 12
M1 - 124201
ER -