Incremental value of radial discoordination index for the prediction of response to cardiac resynchronization therapy

Yi Hsin Chan, Chi Tai Kuo, Yung Hsin Yeh, Lung Sheng Wu, Chun Li Wang*, Wan Jing Ho, Lung An Hsu

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

8 Scopus citations

Abstract

AimsPrevious studies have identified four baseline characteristics associated with a favourable response to cardiac resynchronization therapy (CRT): female, non-ischaemic aetiology of heart failure, left bundle-branch block (LBBB), and QRS duration ≥150 ms. This study evaluated the incremental value of discoordination and dyssynchrony indices over these characteristics for the prediction of the response to CRT.Methods and resultsThe speckle-tracking strain analysis was performed in 120 CRT candidates. Patients were divided into subgroups according to the gender (male vs. female), aetiology of heart failure (ischaemic vs. non-ischaemic), QRS morphology (LBBB vs. non-LBBB), and QRS duration (≥150 vs. <150 ms), respectively. Discoordination was measured using the mid-ventricular radial discoordination index (RDI-M), the ratio of the average mid-ventricular thinning to thickening during ejection. Patients with one of the four favourable characteristics were more likely to exhibit other favourable characteristics and had greater amounts of average myocardial thinning during ejection and RDI-M than those without (all P< 0.05). In contrast, dyssynchrony indices failed to demonstrate significant differences between male and female and between ischaemic and non-ischaemic subjects. Of 39 patients who had 6-month follow-up data after CRT, left ventricular reverse remodelling was found in 22 patients (56%). Combining the favourable characteristics and RDI-M provides the best ability to predict reverse remodelling after CRT (area under the curve = 0.85, 95% confidence interval 0.73-0.98, P < 0.001).ConclusionMechanical discoordination rather than mechanical dyssynchrony provides a significant incremental value over the baseline characteristics for the prediction of the response to CRT.

Original languageEnglish
Pages (from-to)213-222
Number of pages10
JournalEuropean Heart Journal Cardiovascular Imaging
Volume14
Issue number3
DOIs
StatePublished - 03 2013

Keywords

  • Cardiac resynchronization therapy
  • Discoordination
  • Dyssynchrony
  • Echocardiography
  • Speckle tracking

Fingerprint

Dive into the research topics of 'Incremental value of radial discoordination index for the prediction of response to cardiac resynchronization therapy'. Together they form a unique fingerprint.

Cite this