Skip to main navigation Skip to search Skip to main content

Indocyanine green clearance test in non-cirrhotic hepatitis patients: A comparison and analysis between convention blood sampling method and finger piece monitoring method

  • M. Y. Su
  • , D. Y. Lin*
  • , I. S. Sheen
  • , C. M. Chu
  • , C. T. Chiu
  • , Y. F. Liaw
  • *Corresponding author for this work
  • Chang Gung Memorial Hospital

Research output: Contribution to journalJournal Article peer-review

4 Scopus citations

Abstract

Background: The indocyanine green (ICG) Finger Piece Monitor system is a non-invasive method for measuring blood ICG concentrations for the evaluation of hepatic function. This study was conducted to determine its clinical usefulness in non-cirrhotic patients. Methods: Traditional liver function tests, alpha-fetoprotein, prothrombin time, and ICG clearance tests, by both blood sampling method and Finger Piece Monitoring method were performed simultaneously on 56 non-cirrhotic hepatitis patients. The plasma clearance rate (K) and 15-minute retention ration (R15) of ICG were analyzed and compared with traditional liver function test results. Results: The clearance rate using the Finger Piece Monitoring method was slightly lower than that of the blood sampling method (9.16±5.00%/min vs. 11.24±3.56%/min) with good correlation (r=0.721, p=0.0003). The 15-minute retention ratio using the Finger Piece Monitoring method showed better correlation with blood sampling method (32.83±23.99% vs.28.49±23.74%, r=0.944, p=0.0002). Analysis between traditional laboratory tests and fR15 revealed a higher fR15 value in patients with bilirubin-total-T ≥ 3mg/dl (49.71±26.22% vs. 22.23±13.48%), alpha-fetoprotein ≥ 100ng/ml (61.96±15.84% vs. 28.52±21.74%), and PT prolongation ≥ 3 sec (71.46±16.80% vs. 29.03±21.06%). Conclusion: There is a good correlation between the conventional blood sampling method and the ICG Finger Piece Monitoring system method. The ICG Finger Monitoring system provides an alternative for traditional laboratory tests for the evaluation of hepatic dysfunction in hepatitis patients.

Original languageEnglish
Pages (from-to)17-24
Number of pages8
JournalChang Gung Medical Journal
Volume22
Issue number1
StatePublished - 1999
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Finger piece monitoring
  • Hepatitis
  • Indocyanine green clearance test

Fingerprint

Dive into the research topics of 'Indocyanine green clearance test in non-cirrhotic hepatitis patients: A comparison and analysis between convention blood sampling method and finger piece monitoring method'. Together they form a unique fingerprint.

Cite this