Abstract
Two methods are described to cool the kidney. The surface type of device can cover the entire kidney or a single pole. The second method for cooling the kidney is use of an intracellular hypothermic solution with methylprednisolone; the kidney is flushed via the renal artery to achieve cooling. Two interesting cases are presented which illustrate the methods used to achieve hypothermia.
Original language | English |
---|---|
Pages (from-to) | 112-114 |
Number of pages | 3 |
Journal | Urology |
Volume | 15 |
Issue number | 2 |
DOIs | |
State | Published - 02 1980 |
Externally published | Yes |