Skip to main navigation Skip to search Skip to main content

Long-Term Complications of Cranioplasty Using Stored Autologous Bone Graft, Three-Dimensional Polymethyl Methacrylate, or Titanium Mesh After Decompressive Craniectomy: A Single-Center Experience After 596 Procedures

  • Mun Chun Yeap
  • , Po Hsun Tu
  • , Zhuo Hao Liu
  • , Po Chuan Hsieh
  • , Yu Tse Liu
  • , Ching Yi Lee
  • , Hung Yi Lai
  • , Chun Ting Chen
  • , Yin Cheng Huang
  • , Kuo chen Wei
  • , Chieh Tsai Wu
  • , Ching Chang Chen*
  • *Corresponding author for this work
  • Chang Gung Memorial Hospital

Research output: Contribution to journalJournal Article peer-review

88 Scopus citations

Abstract

Objective: Cranioplasty is a technically simple procedure intended to repair defects of the skull to provide protection after craniectomy, improve functional outcomes, and restore cosmesis. Several materials have been used for the restoration of skull defects, including autologous bone grafts (AGs), polymethyl methacrylate (PMMA) flaps, and titanium mesh (T-mesh). However, the long-term results of cranioplasty after use of these materials are controversial. Methods: Medical records of 596 patients who underwent cranioplasty at our medical center between 2009 and 2015 with at least 2.5 years of follow-up were retrospectively reviewed. Patients were classified into 3 groups according to the materials used: AG, three-dimensional PMMA, and T-mesh. Demographic and clinical characteristics and postoperative complications were analyzed. Results: Cranioplasty with AG had the highest bone flap depression rate (4.9%; P = 0.02) and was associated with a 26% long-term bone flap resorption. Younger age was a risk factor for bone flap resorption. T-mesh had a higher risk of postoperative skin erosion and bone exposure (17%; P = 0.004). Patients with diabetes, previous craniotomy, or hydrocephalus showed a higher risk of postoperative skin erosion. PMMA was associated with the highest rate of postoperative infection (14.4% <3 months, 28.1% >3 months; P < 0.05), and previous craniotomy may increase the infection risk after cranioplasty with PMMA. Conclusions: Complications after cranioplasty are high, and the various types of cranioplasty materials used are associated with different complications. Surgeons need to be aware of these potential complications and should choose the appropriate material for each individual patient.

Original languageEnglish
Pages (from-to)e841-e850
JournalWorld Neurosurgery
Volume128
DOIs
StatePublished - 08 2019

Bibliographical note

Publisher Copyright:
© 2019 Elsevier Inc.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • 3D polymethyl methacrylate
  • Autologous bone graft
  • Complication
  • Cranioplasty
  • Titanium mesh

Fingerprint

Dive into the research topics of 'Long-Term Complications of Cranioplasty Using Stored Autologous Bone Graft, Three-Dimensional Polymethyl Methacrylate, or Titanium Mesh After Decompressive Craniectomy: A Single-Center Experience After 596 Procedures'. Together they form a unique fingerprint.

Cite this