Long-term outcomes of radial head arthroplasty in complex elbow fracture dislocation

Alvin Chao Yu Chen*, You Hung Cheng, Chih Hao Chiu, Chun Ying Cheng, Yi Sheng Chan

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

3 Scopus citations

Abstract

The purpose of the current study was to investigate the long-term outcomes of radial head arthroplasty in complex elbow injuries through radiographic analysis and functional correlation. We evaluated 24 radial head arthroplasties in 24 consecutive patients with complex elbow fracture dislocation. All patients were treated with a single type of modular monopolar prosthesis containing smooth stem in press-fit implantation. Clinical survey using the Mayo Elbow Performance Score (MEPS), self-reported scales of shortened Disabilities of the Arm, Shoulder, and Hand (QuickDASH) and the visual analog scale (VAS) at more than 10-year follow-up were reported and compared to 2-year outcomes. Periprosthetic osteolysis was measured in the 10 zones of prosthesis-cortical interface with a modified radiolucency score, which was calibrated by each prosthesis size. Pearson correlation analysis was performed to detect the association between periprosthetic radiolucency and clinical assessment. At the final follow-up, MEPS, QuickDASH score and VAS score averaged 82.5 ± 15, 14.1 ± 14.3 and 1.6 ± 1.2 respectively. A decline in functional status was noted, with decreased mean MEPS and increased mean QuickDASH and VAS scores as compared to the 2-year results while the difference was insignificant. Periprosthetic osteolysis was more prevalent around stem tip of zone 3 and zone 8. The final and 2-year radiolucency scores averaged 7.4 ± 4.2 and 2.6 ± 2.3 respectively with significant difference. Pearson correlation analysis indicated that the difference between radiolucency scores and clinical outcomes in MEPS/QuickDASH/VAS was −0.836, 0.517 and 0.464. Progression of periprosthetic osteolysis after postoperative 10 years is more prevalent around the stem tip with moderate to high correlation to clinical outcomes. Sustained follow-up is warranted to justify subsequent surgery for revision or implant removal.

Original languageEnglish
Article number3488
JournalJournal of Clinical Medicine
Volume10
Issue number16
DOIs
StatePublished - 02 08 2021

Bibliographical note

Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.

Keywords

  • Elbow fracture dislocation
  • Monopolar prosthesis
  • Radial head arthroplasty
  • Radiolucency

Fingerprint

Dive into the research topics of 'Long-term outcomes of radial head arthroplasty in complex elbow fracture dislocation'. Together they form a unique fingerprint.

Cite this