T1 - Longitudinal Guided Wave Inspection of Small-Diameter Elbowed Steel Tubes with a Novel Squirrel-Cage Magnetostrictive Sensor
AU - Liu, Yao
AU - Liu, Xiucheng
AU - Yang, Chehua
AU - Guo, Wenxin
AU - Wu, Bin
AU - He, Cunfu
N1 - Publisher Copyright:
© 2019 Yao Liu et al.
PY - 2019
Y1 - 2019
N2 - In the study, ultrasonic longitudinal mode guided waves were employed to detect defects in elbowed tubes (without welds) with a diameter of 10 mm. Finite element simulation results highlighted that the emitted L(0,1) mode guided waves experienced strong reflection and mode conversion at the elbow region to generate F(1,1) mode, followed by slow and weak F(2,1) mode. The guided wave reflected from the elbow with a through-wall defect was manifested as two overlapped wave packets, which were good indicators of a defective elbow. To conduct L(0,1) mode guided waves inspection on the small-diameter elbowed tubes, a novel tailored squirrel-cage magnetostrictive sensor was employed in the experiment. The new sensor employed the configuration of segmental iron-cobalt strips and small-size permanent magnet arrays. The entire sensor is composed of two identical C-shaped sensor elements and can be recycled and installed conveniently. Experimental results obtained from healthy and defective tubes were consistent with the conclusions obtained from finite element simulations. An artificial through-wall defect at the elbow and a notch defect at the straight part of the tube could be simultaneously detected by L(0,1) mode guided waves through comparing experimental signals with simulation results.
AB - In the study, ultrasonic longitudinal mode guided waves were employed to detect defects in elbowed tubes (without welds) with a diameter of 10 mm. Finite element simulation results highlighted that the emitted L(0,1) mode guided waves experienced strong reflection and mode conversion at the elbow region to generate F(1,1) mode, followed by slow and weak F(2,1) mode. The guided wave reflected from the elbow with a through-wall defect was manifested as two overlapped wave packets, which were good indicators of a defective elbow. To conduct L(0,1) mode guided waves inspection on the small-diameter elbowed tubes, a novel tailored squirrel-cage magnetostrictive sensor was employed in the experiment. The new sensor employed the configuration of segmental iron-cobalt strips and small-size permanent magnet arrays. The entire sensor is composed of two identical C-shaped sensor elements and can be recycled and installed conveniently. Experimental results obtained from healthy and defective tubes were consistent with the conclusions obtained from finite element simulations. An artificial through-wall defect at the elbow and a notch defect at the straight part of the tube could be simultaneously detected by L(0,1) mode guided waves through comparing experimental signals with simulation results.
UR - http://www.scopus.com/inward/record.url?scp=85075736806&partnerID=8YFLogxK
U2 - 10.1155/2019/3027372
DO - 10.1155/2019/3027372
M3 - 文章
AN - SCOPUS:85075736806
SN - 1687-725X
VL - 2019
JO - Journal of Sensors
JF - Journal of Sensors
M1 - 3027372
ER -