Skip to main navigation Skip to search Skip to main content

Midline Dose Verification with Diode In Vivo Dosimetry for External Photon Therapy of Head and Neck and Pelvis Cancers During Initial Large-Field Treatments

  • Chuan Jong Tung
  • , Pei Chieh Yu
  • , Min Chi Chiu
  • , Chi Yuan Yeh
  • , Chung Chi Lee
  • , Tsi Chian Chao*
  • *Corresponding author for this work
  • National Tsing Hua University
  • Cathay General Hospital Taiwan
  • Taipei Medical University
  • Tungs' Taichung MetroHarbor Hospital

Research output: Contribution to journal › Journal Article › peer-review

5 Scopus citations

Abstract

During radiotherapy treatments, quality assurance/control is essential, particularly dose delivery to patients. This study was designed to verify midline doses with diode in vivo dosimetry. Dosimetry was studied for 6-MV bilateral fields in head and neck cancer treatments and 10-MV bilateral and anteroposterior/posteroanterior (AP/PA) fields in pelvic cancer treatments. Calibrations with corrections of diodes were performed using plastic water phantoms; 190 and 100 portals were studied for head and neck and pelvis treatments, respectively. Calculations of midline doses were made using the midline transmission, arithmetic mean, and geometric mean algorithms. These midline doses were compared with the treatment planning system target doses for lateral or AP (PA) portals and paired opposed portals. For head and neck treatments, all 3 algorithms were satisfactory, although the geometric mean algorithm was less accurate and more uncertain. For pelvis treatments, the arithmetic mean algorithm seemed unacceptable, whereas the other algorithms were satisfactory. The random error was reduced by using averaged midline doses of paired opposed portals because the asymmetric effect was averaged out. Considering the simplicity of in vivo dosimetry, the arithmetic mean and geometric mean algorithm should be adopted for head/neck and pelvis treatments, respectively.

Original languageEnglish
Pages (from-to)304-311
Number of pages8
JournalMedical Dosimetry
Volume35
Issue number4
DOIs
StatePublished - 2010

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Diode
  • Head and neck cancer
  • In vivo dosimetry
  • Pelvis cancer
  • Radiotherapy

Fingerprint

Dive into the research topics of 'Midline Dose Verification with Diode In Vivo Dosimetry for External Photon Therapy of Head and Neck and Pelvis Cancers During Initial Large-Field Treatments'. Together they form a unique fingerprint.

Cite this