Monitoring radiofrequency ablation using ultrasound envelope statistics and shear wave elastography in the periablation period: An in vitro feasibility study

  • Chang Gung University
  • Beijing University of Technology

Research output: Contribution to journalJournal Article peer-review

16 Scopus citations

Abstract

Radiofrequency ablation (RFA) is a minimally invasive method for treating tumors. Shear wave elastography (SWE) has been widely applied in evaluating tissue stiffness and final ablation size after RFA. However, the usefulness of periablation SWE imaging in assessing RFA remains unclear. Therefore, this study investigated the correlation between periablation SWE imaging and final ablation size. An in vitro porcine liver model was used for experimental validation (n = 36). During RFA with a power of 50 W, SWE images were collected using a clinical ultrasound system. To evaluate the effects of tissue temperature and gas bubbles during RFA, changes in the ablation temperature were recorded, and image echo patterns were measured using B-mode and ultrasound statistical parametric images. After RFA, the gross pathology of each tissue sample was compared with the region of change in the corresponding periablation SWE image. The experimental results showed that the tissue temperature at the ablation site varied between 70° C and 100° C. Hyperechoic regions and changes were observed in the echo amplitude distribution induced by gas bubbles. Under this condition, the confounding effects (including the temperature increase, tissue stiffness increase, and presence of gas bubbles) resulted in artifacts in the periablation SWE images, and the corresponding region correlated with the estimated final ablation size obtained from the gross pathology (r = 0.8). The findings confirm the feasibility of using periablation SWE imaging in assessing RFA.

Original languageEnglish
Article numbere0162488
JournalPLoS ONE
Volume11
Issue number9
DOIs
StatePublished - 09 2016

Bibliographical note

Publisher Copyright:
© 2016 Tsui et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Fingerprint

Dive into the research topics of 'Monitoring radiofrequency ablation using ultrasound envelope statistics and shear wave elastography in the periablation period: An in vitro feasibility study'. Together they form a unique fingerprint.

Cite this