TY - JOUR
T1 - Multimodality quantitative ultrasound envelope statistics imaging based support vector machines for characterizing tissue scatterer distribution patterns
T2 - Methods and application in detecting microwave-induced thermal lesions
AU - Li, Sinan
AU - Tsui, Po Hsiang
AU - Wu, Weiwei
AU - Zhou, Zhuhuang
AU - Wu, Shuicai
N1 - Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.
PY - 2024/7
Y1 - 2024/7
N2 - Ultrasound envelope statistics imaging, including ultrasound Nakagami imaging, homodyned-K imaging, and information entropy imaging, is an important group of quantitative ultrasound techniques for characterizing tissue scatterer distribution patterns, such as scatterer concentrations and arrangements. In this study, we proposed a machine learning approach to integrate the strength of multimodality quantitative ultrasound envelope statistics imaging techniques and applied it to detecting microwave ablation induced thermal lesions in porcine liver ex vivo. The quantitative ultrasound parameters included were homodyned-K α which is a scatterer clustering parameter related to the effective scatterer number per resolution cell, Nakagami m which is a shape parameter of the envelope probability density function, and Shannon entropy which is a measure of signal uncertainty or complexity. Specifically, the homodyned-K log
10(α), Nakagami-m, and horizontally normalized Shannon entropy parameters were combined as input features to train a support vector machine (SVM) model to classify thermal lesions with higher scatterer concentrations from normal tissues with lower scatterer concentrations. Through heterogeneous phantom simulations based on Field II, the proposed SVM model showed a classification accuracy above 0.90; the area accuracy and Dice score of higher-scatterer-concentration zone identification exceeded 83% and 0.86, respectively, with the Hausdorff distance <26. Microwave ablation experiments of porcine liver ex vivo at 60-80 W, 1-3 min showed that the SVM model achieved a classification accuracy of 0.85; compared with single log
10(α),m, or hNSE parametric imaging, the SVM model achieved the highest area accuracy (89.1%) and Dice score (0.77) as well as the smallest Hausdorff distance (46.38) of coagulation zone identification. We concluded that the proposed multimodality quantitative ultrasound envelope statistics imaging based SVM approach can enhance the capability to characterize tissue scatterer distribution patterns and has the potential to detect the thermal lesions induced by microwave ablation.
AB - Ultrasound envelope statistics imaging, including ultrasound Nakagami imaging, homodyned-K imaging, and information entropy imaging, is an important group of quantitative ultrasound techniques for characterizing tissue scatterer distribution patterns, such as scatterer concentrations and arrangements. In this study, we proposed a machine learning approach to integrate the strength of multimodality quantitative ultrasound envelope statistics imaging techniques and applied it to detecting microwave ablation induced thermal lesions in porcine liver ex vivo. The quantitative ultrasound parameters included were homodyned-K α which is a scatterer clustering parameter related to the effective scatterer number per resolution cell, Nakagami m which is a shape parameter of the envelope probability density function, and Shannon entropy which is a measure of signal uncertainty or complexity. Specifically, the homodyned-K log
10(α), Nakagami-m, and horizontally normalized Shannon entropy parameters were combined as input features to train a support vector machine (SVM) model to classify thermal lesions with higher scatterer concentrations from normal tissues with lower scatterer concentrations. Through heterogeneous phantom simulations based on Field II, the proposed SVM model showed a classification accuracy above 0.90; the area accuracy and Dice score of higher-scatterer-concentration zone identification exceeded 83% and 0.86, respectively, with the Hausdorff distance <26. Microwave ablation experiments of porcine liver ex vivo at 60-80 W, 1-3 min showed that the SVM model achieved a classification accuracy of 0.85; compared with single log
10(α),m, or hNSE parametric imaging, the SVM model achieved the highest area accuracy (89.1%) and Dice score (0.77) as well as the smallest Hausdorff distance (46.38) of coagulation zone identification. We concluded that the proposed multimodality quantitative ultrasound envelope statistics imaging based SVM approach can enhance the capability to characterize tissue scatterer distribution patterns and has the potential to detect the thermal lesions induced by microwave ablation.
KW - Machine learning
KW - Multimodality ultrasound envelope statistics imaging
KW - Quantitative ultrasound
KW - Tissue scatterer distribution
KW - Ultrasound tissue characterization
UR - http://www.scopus.com/inward/record.url?scp=85193485837&partnerID=8YFLogxK
U2 - 10.1016/j.ultsonch.2024.106910
DO - 10.1016/j.ultsonch.2024.106910
M3 - 文章
C2 - 38772312
AN - SCOPUS:85193485837
SN - 1350-4177
VL - 107
SP - 106910
JO - Ultrasonics Sonochemistry
JF - Ultrasonics Sonochemistry
M1 - 106910
ER -