TY - JOUR
T1 - Nh3 plasma-treated magnesium doped zinc oxide in biomedical sensors with electrolyte–insulator– semiconductor (Eis) structure for urea and glucose applications
AU - Lin, Chun Fu
AU - Kao, Chyuan Haur
AU - Lin, Chan Yu
AU - Chen, Kuan Lin
AU - Lin, Yun Hao
N1 - Publisher Copyright:
© 2020 by the authors.
PY - 2020/3
Y1 - 2020/3
N2 - This study compared the sensing characteristics of ZnO (ZO) treated with ammonia (NH3) plasma for 1 min, 3 min, and 6 min, under the EIS structure. The measurement results revealed that, after 3 min of NH3 plasma treatment, the Mg-doped ZnO (MZO) sensing film had a high hydrogen ion sensitivity, linearity, hysteresis, and drift rate of 53.82 mV/pH, 99.04%, 2.52 mV, and 1.75 mV/h, respectively. The sensing film was used with sodium and potassium ion solutions, and it performed satisfactorily in sensing hydrogen ions. Additionally, we investigated the biomedical sensing properties of Mg-doped ZnO (MZO) sensing film with regard to urea, creatinine, and glucose solutions and found that the Mg-doped ZnO (MZO) sensing film treated with NH3 plasma for 3 min had the best properties for sensing urea, creatinine, and glucose. Specifically, with glucose, the sensing film achieved the best linearity and sensitivity and of 97.87% and 10.73 mV/mM, respectively. The results revealed that the sensing characteristics varied with the processing environment and are useful in the developing biomedical sensing applications with different sensing elements.
AB - This study compared the sensing characteristics of ZnO (ZO) treated with ammonia (NH3) plasma for 1 min, 3 min, and 6 min, under the EIS structure. The measurement results revealed that, after 3 min of NH3 plasma treatment, the Mg-doped ZnO (MZO) sensing film had a high hydrogen ion sensitivity, linearity, hysteresis, and drift rate of 53.82 mV/pH, 99.04%, 2.52 mV, and 1.75 mV/h, respectively. The sensing film was used with sodium and potassium ion solutions, and it performed satisfactorily in sensing hydrogen ions. Additionally, we investigated the biomedical sensing properties of Mg-doped ZnO (MZO) sensing film with regard to urea, creatinine, and glucose solutions and found that the Mg-doped ZnO (MZO) sensing film treated with NH3 plasma for 3 min had the best properties for sensing urea, creatinine, and glucose. Specifically, with glucose, the sensing film achieved the best linearity and sensitivity and of 97.87% and 10.73 mV/mM, respectively. The results revealed that the sensing characteristics varied with the processing environment and are useful in the developing biomedical sensing applications with different sensing elements.
KW - Biomedical sensors
KW - Glucose and urea
KW - Mg-doped ZO (MZO) film
KW - NH plasma
UR - https://www.scopus.com/pages/publications/85082957485
U2 - 10.3390/nano10030583
DO - 10.3390/nano10030583
M3 - 文章
AN - SCOPUS:85082957485
SN - 2079-4991
VL - 10
JO - Nanomaterials
JF - Nanomaterials
IS - 3
M1 - 583
ER -