Skip to main navigation Skip to search Skip to main content

Novel Measurement System for Linear Array Type UVC Germicidal System

  • Tal Ping Sun
  • , Chung Ta Huang
  • , Ping Wing Lui
  • , Yi Tai Chen
  • , Hsiu Li Shieh
  • Nan Kai University of Technology
  • National Chi Nan University
  • Veterans General Hospital-Taichung Taiwan

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution › peer-review

6 Scopus citations

Abstract

The germicidal system is constructed using a UVC LED illumination module with a wavelength of 275 nm and a power of 1.8 mw. UVC LED has a smaller volume without heat radiation and pollution that meets the requirements of green energy and environmental protection. It is very suitable for sterilization and purification. It can destroy microbiological organisms such as bacteria, viruses, or spores, etc., of their molecular structure of DNA (deoxyribonucleic acid) and RNA (ribonucleic acid) in pathogen cells, which causes the cells to lose the ability to replicate and regenerate, thereby achieving germicidal efficacy. The UVC Germicidal System (abbreviated as UVCGS) is designed with an array of UVC LEDs. The key technologies of the UVCGSs' drive circuit is a new automatic power control system (APC) design, which can make UVC LED in constant current mode and stable electric power for operation. That is, when the power of the UVC LED changes with temperature, the current amount can be automatically adjusted by the driving circuit. So that the UVC LED can be maintained at a different temperature and still keep a stable optical power output to achieve temperature compensation purpose. The design of the drive circuit confirms that the UVCGS being operated at different temperature changes from 0 °C 35 °C and with stable current and stable optical power output capability can sterilize Escherichia coli, Staphylococcus aureus, Acinetobacter baumannii, etc., achieving multiple germicidal benefits. Among them, Acinetobacter baumannii has been experimentally analyzed that within 2-20 seconds of irradiation time, under the condition of average sterilization residual amount at different heights, the proper bactericidal residual amount is about 12-13 (lethal rate is 91-92%, \text{UVGI}=12), and the required minimum germicidal irradiation power dose is 1500\mu \text{W}- Sec/cm2, which meets UVGI standard values and typical lethality standards.

Original languageEnglish
Title of host publicationProceedings of 2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability, ECBIOS 2019
EditorsTeen-Hang Meen
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages57-60
Number of pages4
ISBN (Electronic)9781728107639
DOIs
StatePublished - 05 2019
Externally publishedYes
Event2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability, ECBIOS 2019 - Okinawa, Japan
Duration: 31 05 2019 → 03 06 2019

Publication series

NameProceedings of 2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability, ECBIOS 2019

Conference

Conference2019 IEEE Eurasia Conference on Biomedical Engineering, Healthcare and Sustainability, ECBIOS 2019
Country/TerritoryJapan
CityOkinawa
Period31/05/19 → 03/06/19

Bibliographical note

Publisher Copyright:
© 2019 IEEE.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • APC
  • UVC LED
  • UVCGS
  • UVGI

Fingerprint

Dive into the research topics of 'Novel Measurement System for Linear Array Type UVC Germicidal System'. Together they form a unique fingerprint.