Rapid diagnosis of periprosthetic joint infection from synovial fluid in blood culture bottles by direct matrix-assisted laser desorption ionization time-of-flight mass spectrometry

Feng Chih Kuo, Chun Chih Chien, Mel S. Lee, Jun Wen Wang, Po Chun Lin, Chen Hsiang Lee*

*Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

16 Scopus citations

Abstract

Background The aim of this prospective study was to use direct matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) to rapidly diagnose periprosthetic joint infections (PJIs). Method Synovial fluid was taken from 77 patients (80 joints, 41 hips and 39 knees) who met the International Consensus Meeting criteria for PJI, and inoculated into blood culture bottles (BCBs) and onto conventional swabs. Positive blood cultures were analyzed using either direct or routine MALDI-TOF MS. Pathogen identification and the time to identification was recorded. Differences between groups were analyzed using the Kruskal-Wallis test and Bonferroni’s post-hoc test. Results Direct and routine MALDI-TOF MS both detected 64 positive results (80%), compared to 47 (59%) by conventional swabs (p = 0.002). Direct MALDI-TOF MS identified 85.3% of the gram-positive organisms and 92.3% of the gram-negative organisms. No fungi were identified by direct MALDI-TOF MS. In 17 BCBs that were flagged positive, identification by direct MALDI-TOF MS failed. Among the positive results in the direct MALDI-TOF MS group, Staphylococcus aureus accounted for 47%, followed by Staphylococcus epidermidis (17%), Escherichia coli (9%) and Klebsiella pneumoniae (9%). The median time to microorganism identification was significantly shorter with direct MALDI-TOF MS (12.7 h, IQR: 8.9–19.6 h) than with routine MALDI-TOF MS (39.5 h, IQR: 22.8–46.0 h) or swabs (44.4 h, IQR: 27.2–72.6 h) (p < 0.0001). In pairwise comparisons, there were significant differences in the time of microorganism identification between direct MALDI-TOF MS and routine MALDI-TOF MS (p < 0.0001) or swab culture (p < 0.0001). There was no significant difference between routine MALDI-TOF MS and swab culture (p = 0.0268). Conclusion Compared with current laboratory practice, direct MALDI-TOF MS shortened the time to microorganism identification and had superior results compared to conventional swabs, except for fungi. Further studies should investigate whether the earlier administration of appropriate antimicrobial agents can improve the treatment outcomes of PJIs.

Original languageEnglish
Article numbere0239290
JournalPLoS ONE
Volume15
Issue number9 September
DOIs
StatePublished - 09 2020

Bibliographical note

Publisher Copyright:
Copyright: © 2020 Kuo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Fingerprint

Dive into the research topics of 'Rapid diagnosis of periprosthetic joint infection from synovial fluid in blood culture bottles by direct matrix-assisted laser desorption ionization time-of-flight mass spectrometry'. Together they form a unique fingerprint.

Cite this