Abstract
In order to obtain a relative accuracy of lifetime prediction of reliability test for VCSEL array device, the junction temperature (Tj) extraction has been investigated and analyzed in this manuscript. We propose a modified array thermal model which is achieved by unit area including 2 × 2 emitters based on the thermal characterizations of single emitter and array device. Adopting the additional parameters of thermal coupling and common thermal dissipation path into the model, peak and average Tj can be analyzed for the VCSEL array within 380 emitters under pulsed or CW operation. To further verify the Tj extraction with a certain pulse condition, accelerated life testing (ALT) was performed for a criteria of 5 % power degradation at operating current (Iop). The array lifetime prediction can be analyzed by the calculation of temperature acceleration factor (EA) and current acceleration factor (n) with the modified Tj value.
| Original language | English |
|---|---|
| Pages | 113-116 |
| Number of pages | 4 |
| State | Published - 2022 |
| Event | 2022 International Conference on Compound Semiconductor Manufacturing Technology, CS MANTECH 2022 - Monterey, United States Duration: 09 05 2022 → 12 05 2022 |
Conference
| Conference | 2022 International Conference on Compound Semiconductor Manufacturing Technology, CS MANTECH 2022 |
|---|---|
| Country/Territory | United States |
| City | Monterey |
| Period | 09/05/22 → 12/05/22 |
Bibliographical note
Publisher Copyright:© 2022 MANTECH 2022. All rights reserved.
Keywords
- VCSEL
- pulsed mode
- thermal analysis