Reverse breakdown voltage measurement for power P+NN+ rectifier

  • Nanyang Technological University

Research output: Contribution to journal › Journal Article › peer-review

Abstract

The measurement of the reverse breakdown voltage for power rectifier is an important test. Two test methods for the reverse breakdown voltage measurement are employed in the industry, namely the forced voltage test (FVT) and the forced current test (FCT). In this work, we perform a systematic study to explain the different breakdown voltages obtained from the two test methods and the possible damage mechanisms to the device under test during FVT and FCT. The study shows that FVT has a much shorter test time while FCT is less destructive to the device under test.

Original languageEnglish
Pages (from-to)473-479
Number of pages7
JournalJournal of Electronic Testing: Theory and Applications (JETTA)
Volume24
Issue number5
DOIs
StatePublished - 10 2008
Externally publishedYes

Keywords

  • Destruction during test
  • Forced current test
  • Forced voltage test
  • Minimum required test time
  • PIV test