TY - JOUR
T1 - Separation of dsDNA in the presence of electroosmotic flow under discontinuous conditions
AU - Huang, Ming Feng
AU - Hsu, Chien En
AU - Tseng, Wei Lung
AU - Lin, Yu Cheng
AU - Chang, Huan Tsung
PY - 2001
Y1 - 2001
N2 - Separations of X-174/Haelll DNA restriction fragments have been performed in the presence of electroosmotic flow (EOF) using five different polymer solutions, including linear polyacrylamide (LPA), poly(ethylene oxide) (PEO), hydroxypropylcellulose (HPC), hydroxyethylcellulose (HEC), and agarose. During the separation, polymer solutions entered the capillary by EOF. When using LPA solutions, bulk EOF is small due to adsorption on the capillary wall. On the other hand, separation is faster and better for the large DNA fragments (> 872 base pairs, bp) using derivative celluloses and PEO solutions. Several approaches to optimum resolution and speed by controlling EOF and/or altering electrophoretic mobility of DNA have been developed, including (i) stepwise changes of ethidium bromide (0.5-5 μg/mL), (ii) voltage programming (125-375 V/cm), (iii) use of mixed polymer solutions, and (iv) use of high concentrations of Tris-borate (TB) buffers. The DNA fragments ranging from 434 to 653 bp that were not separated using 2% PEO (8 000 000) under isocratic conditions have been completely resolved by either stepwise changes of ethidium bromide or voltage programming. Compared to PEO solutions, mixed polymer solutions prepared from PEO and HEC provide higher resolving power. Using a capillary filled with 600 mM TB buffers, pH 10.0, high-speed (< 15 min) separation of DNA (pBR 322/Haelll digest, pBR 328/ Bg/l digest and pBR 328/Hinfl digest) has been achieved in 1.5% PEO.
AB - Separations of X-174/Haelll DNA restriction fragments have been performed in the presence of electroosmotic flow (EOF) using five different polymer solutions, including linear polyacrylamide (LPA), poly(ethylene oxide) (PEO), hydroxypropylcellulose (HPC), hydroxyethylcellulose (HEC), and agarose. During the separation, polymer solutions entered the capillary by EOF. When using LPA solutions, bulk EOF is small due to adsorption on the capillary wall. On the other hand, separation is faster and better for the large DNA fragments (> 872 base pairs, bp) using derivative celluloses and PEO solutions. Several approaches to optimum resolution and speed by controlling EOF and/or altering electrophoretic mobility of DNA have been developed, including (i) stepwise changes of ethidium bromide (0.5-5 μg/mL), (ii) voltage programming (125-375 V/cm), (iii) use of mixed polymer solutions, and (iv) use of high concentrations of Tris-borate (TB) buffers. The DNA fragments ranging from 434 to 653 bp that were not separated using 2% PEO (8 000 000) under isocratic conditions have been completely resolved by either stepwise changes of ethidium bromide or voltage programming. Compared to PEO solutions, mixed polymer solutions prepared from PEO and HEC provide higher resolving power. Using a capillary filled with 600 mM TB buffers, pH 10.0, high-speed (< 15 min) separation of DNA (pBR 322/Haelll digest, pBR 328/ Bg/l digest and pBR 328/Hinfl digest) has been achieved in 1.5% PEO.
KW - Capillary electrophoresis
KW - DNA
KW - Laser-induced fluorescence
KW - Polymer solutions
UR - http://www.scopus.com/inward/record.url?scp=0034928587&partnerID=8YFLogxK
U2 - 10.1002/1522-2683(20017)22:11<2281::AID-ELPS2281>3.0.CO;2-C
DO - 10.1002/1522-2683(20017)22:11<2281::AID-ELPS2281>3.0.CO;2-C
M3 - 文章
C2 - 11504063
AN - SCOPUS:0034928587
SN - 0173-0835
VL - 22
SP - 2281
EP - 2290
JO - Electrophoresis
JF - Electrophoresis
IS - 11
ER -