SU‐GG‐I‐124: A Universal Analysis On Temporal Uncertainty of FMRI Methods with Different Biophysical Mechanisms

H. Liu, Y. Hong, Yau‐yau Wai

Research output: Contribution to journalJournal Article peer-review

Abstract

Purpose: Functional MRI (fMRI) using BOLD contrast has been widely applied to localize brain activations. However, the venous origin of the BOLD signal can cause varied temporal uncertainties in different brain regions. Besides the vasculature variations, determination of the BOLD response timing is also affected by the contrast‐to‐noise ratio (CNR). In this study, we propose a universal analysis to differentiate the temporal uncertainty resulted from different biophysical mechanisms. The analysis was applied to compare CBV‐ and BOLD‐based experiments at different field strengths. Method and Materials: Eight normal volunteers participated in this study (3 at a 1.5T Vision and 5 subjects at a 3T Tim‐Trio scanner). A GE‐EPI was used for the BOLD experiment (TR/TE/FA = 1000ms/60ms/90° at 1.5T and 1000ms/35ms/64° at 3T). A non‐slice‐selective IR‐GE‐EPI sequence was used for the vascular space occupancy (VASO) experiment (TI/TR/TE/FA = 665 ms/2000ms/9.3ms/90° at 1.5T and 710ms/2000ms/12ms/90° at 3T). Each experiment contained 30 repeated trials of brief (1s) visual stimulation. CNR and response onset time were quantified for each activated voxels in the visual area. Results: The measured CNR increased with number of trials averaged. The plot of the standard deviation of onset time (ΔT) vs. CNR was able to differentiated VASO from BOLD results, showing less onset variations in the VASO measurements when comparing at the same CNR levels. The same two curves (BOLD and VASO) were able to describe results obtained at different field strengths, i.e. 1.5T and 3T results shared the same curves with 3T shifted to higher CNR regions. Conclusion: We proposed to analyze temporal uncertainty of HRs measured in fMRI at different CNRs which were manipulated by averaging different numbers of repeated trials. The results demonstrated that this analysis was universal to measurements at different field strengths and able to characterize distinguished biophysical mechanisms of different fMRI methods.

Original languageEnglish
Pages (from-to)2670
Number of pages1
JournalMedical Physics
Volume35
Issue number6
DOIs
StatePublished - 06 2008
Externally publishedYes

Fingerprint

Dive into the research topics of 'SU‐GG‐I‐124: A Universal Analysis On Temporal Uncertainty of FMRI Methods with Different Biophysical Mechanisms'. Together they form a unique fingerprint.

Cite this