Susceptibility of iodine concentration map of dual-energy contrast-enhanced digital mammography for quantitative and tumor enhancement assessment

  • Yi Shuan Hwang
  • , Yun Chung Cheung
  • , Yu Ying Lin
  • , Hsiao Lan Hsu
  • , Hui Yu Tsai*
  • *Corresponding author for this work

Research output: Contribution to journalJournal Article peer-review

6 Scopus citations

Abstract

Background: Dual-energy (DE) contrast-enhanced digital mammography (DE-CEDM) provides additional information on tumor angiogenesis. Purpose: To investigate the susceptibility of reconstructing color-coded iodine concentration maps on the basis of quantitative calibrations of the iodine concentration and contrast-to-noise ratio (CNR) in DE-CEDM applications. Material and Methods: A custom-made phantom filled with iodine concentrations in the range of 0.1–10 mg/cm2 was used in calibrations. All DE images were acquired using the GE Senographe Essential system. From DE subtraction images, the image contrast and CNR were obtained, and the quantitative relationship between these two metrics and the iodine concentration at each phantom thickness was investigated. The quantitative CNR calibration curves were applied to reconstruct color-coded iodine maps on a pixel-by-pixel basis. Results: Both the mean contrast and mean CNR increased linearly with the iodine concentration. The iodine concentration estimated from the iodine map reconstructed from quantitative CNR calibrations was highly consistent with the desired iodine concentration (R2= 0.989), and smaller relative errors (in the range of 3.0–19.5%) were observed with iodine concentrations not less than 1 mg/cm2. Conclusion: An iodine concentration map could be reconstructed based on the linear relationship between the CNR and iodine concentration. From the color-coded iodine concentration map, the contrast medium enhancement phenomenon could be further estimated quantitatively, and tumor enhancement patterns could be easily observed.

Original languageEnglish
Pages (from-to)893-901
Number of pages9
JournalActa Radiologica
Volume59
Issue number8
DOIs
StatePublished - 01 08 2018

Bibliographical note

Publisher Copyright:
© 2017, The Foundation Acta Radiologica.

Keywords

  • Dual energy
  • contrast medium
  • contrast-enhanced digital mammography
  • iodine concentration

Fingerprint

Dive into the research topics of 'Susceptibility of iodine concentration map of dual-energy contrast-enhanced digital mammography for quantitative and tumor enhancement assessment'. Together they form a unique fingerprint.

Cite this