Skip to main navigation Skip to search Skip to main content

The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - A finite element simulation

  • Ching Lung Tai
  • , Yung Chou Chen
  • , Pang Hsin Hsieh*
  • *Corresponding author for this work
  • Chang Gung University

Research output: Contribution to journalJournal Article peer-review

12 Scopus citations

Abstract

Background: Due to the advantages of its bone-conserving nature, hip resurface arthroplasty (HRA) has recently gained the interest of orthopedic surgeons for the treatment of young and active patients who have osteonerosis of the femoral head. However, in long-term follow-up studies after HRA, narrowing of the femoral neck has often been found, which may lead to fracture. This phenomenon has been attributed to the stress alteration (stress shielding). Studies addressing the effects of necrotic size and the orientation of the implant on stress alterations are lacking. Methods. Computed tomography images of a standard composite femur were used to create a three-dimensional finite-element (FE) intact femur model. Based on the intact model, FE models simulating four different levels of necrotic regions (0°, 60°, 100°, 115°) and three different implant insertion angles (varus 10°, neutral, valgus 10°) were created. The von Mises stress distributions and the displacement of the stem tip of each model were analyzed and compared for loading conditions that simulated a single-legged stance. Results: Stress shielding occurred at the femoral neck after HRA. More severe stress shielding and an increased displacement of the stem tip were found for femoral heads that had a wider necrotic lesion. From a biomechanics perspective, the results were consistent with clinical evidence of femoral neck narrowing after HRA. In addition, a varus orientation of the implant resulted in a larger displacement of the stem tip, which could lead to an increased risk of implant loosening. Conclusions: A femoral head with a wide necrotic lesion combined with a varus orientation of the prosthesis increases the risk of femoral neck narrowing and implant loosening following HRA.

Original languageEnglish
Article number262
JournalBMC Musculoskeletal Disorders
Volume15
Issue number1
DOIs
StatePublished - 05 08 2014

Bibliographical note

Publisher Copyright:
© 2014 Tai et al.; licensee BioMed Central Ltd.

Keywords

  • Femoral head necrosis
  • Finite element analysis
  • Hip resurfacing
  • Stress shielding

Fingerprint

Dive into the research topics of 'The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - A finite element simulation'. Together they form a unique fingerprint.

Cite this