The population effective dose of medical computed tomography examinations in Taiwan for 2013

Da Ming Yeh, Hui Yu Tsai, Yen Sheng Tyan, Yu Cheng Chang, Lung Kwang Pan, Tou Rong Chen

Research output: Contribution to journalJournal Article peer-review

13 Scopus citations

Abstract

Purpose: To evaluate the annual effective dose per capita attributed to computed tomography (CT) examinations in 2013 and to predict the population effective dose from 2000 to 2013 in Taiwan. Methods: A CT examination database collected from 30 hospitals was divided into 22 procedures and classified into six regions: head, neck, chest, abdomen, pelvis, and other, respectively. The effective doses in different regions were evaluated by dose-length product (DLP) multiplied by conversion factors. Results: The CT scan dose parameters were collected from 4,407 patients. For the six scanned regions, the percentages of patients scanned were: head (39.8%), neck (3.9%), chest (23.3%), abdomen (26.7%), pelvis (4.8%), and other (1.6%), respectively. The DLPs per patient (mGy·cm/patient) were head (1,071±225), neck (1,103±615), chest (724±509), abdomen (1,315±550), pelvis (1,231±620) and other (1,407±937), respectively. The number of CT examinations increased rapidly, with an average annual growth rate of 7.6%. The number of CT examinations in 2013 was 2.6 times that in 2000. The population effective dose was 0.30 mSv per capita in 2000 and increased to 0.74 mSv per capita in 2013, with an annual growth rate of 7.2%. The growth trend indicates that the effective dose will continue to rise in Taiwan. Conclusion: Some strategies should be applied to cope with this growth. Defining the CT dose reference level stipulated in official recommendations and encouraging the use of iterative reconstruction imaging instead of filtered back-projection imaging could be a useful method for optimizing the effective dose and image quality.

Original languageEnglish
Article numbere0165526
JournalPLoS ONE
Volume11
Issue number10
DOIs
StatePublished - 10 2016

Bibliographical note

Publisher Copyright:
© 2016 Yeh et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Fingerprint

Dive into the research topics of 'The population effective dose of medical computed tomography examinations in Taiwan for 2013'. Together they form a unique fingerprint.

Cite this