A modified approach for elbow arthroscopy using an adjustable arm holder

  • Alvin Chao Yu Chen*
  • , Chun Jui Weng
  • , Chih Hao Chiu
  • , Shih Sheng Chang
  • , Chun Ying Cheng
  • , Yi Sheng Chan
  • *此作品的通信作者

研究成果: 期刊稿件文章同行評審

6 引文 斯高帕斯(Scopus)

摘要

Background: Position shifting from elbow arthroscopy to open surgery could complicate the surgical procedures; patient safety and risks of contamination are of concern. The aim of this study is to retrospectively assess the safety and efficacy of elbow arthroscopy in 32 elbows of 32 patients using a modified arm holder to facilitate subsequent open surgery in supine position. Methods: We performed a retrospective study in arthroscopy of the elbow performed with patients in the supine position under general or regional anesthesia. Arthroscopic indications were intraarticular lesions with or without second disorders. The operated arm was securely supported using an adjustable arm holder, which allowed a second surgical procedure without repositioning the patient. We recorded arthroscopic findings, clinical outcome, and complications for all patients. The average duration of follow-up was 17.1 months. Functional assessment was based on the Mayo Elbow Performance Score. Results: All patients had either good or excellent results with a mean Mayo Elbow Performance Score of 89.2 ± 7.2. Final motion arc averaged 113.3 ± 11.8; residual motion limitation was noted in 2 patients with preoperative ankylosis. No complications were observed immediately after surgery or during follow-up except transient paresthesia along medial cutaneous nerve in 2 patients. A total of 17 patients (53.1%) underwent other surgeries (19 procedures) after arthroscopy; 16 of these surgeries were open elbow procedures including ligament repair (7), ligament reconstruction (5), and ulnar nerve transposition (4). The average time for arthroscopy was 45.2 min; the time interval between the end of arthroscopy and the start of the second surgery procedure averaged 6.5 min. Conclusions: Arthroscopy of the elbow using an adjustable arm holder with the patients in the supine position was safe and efficacious. This procedure eliminates the need for repositioning the patient and thus may facilitate subsequent concomitant surgical procedures.

原文英語
文章編號20
期刊Journal of Orthopaedic Surgery and Research
12
發行號1
DOIs
出版狀態已出版 - 31 01 2017
對外發佈

文獻附註

Publisher Copyright:
© 2017 The Author(s).

指紋

深入研究「A modified approach for elbow arthroscopy using an adjustable arm holder」主題。共同形成了獨特的指紋。

引用此