A system model for pinhole SPECT simulating edge penetration, detector and pinhole response and non-uniform attenuation

Christian Wietholt*, Ing Tsung Hsiao, Chin Tu Chen

*此作品的通信作者

研究成果: 圖書/報告稿件的類型會議稿件同行評審

2 引文 斯高帕斯(Scopus)

摘要

Small animal SPECT using low energy photons of I-125 and approaching resolutions of microscopic levels, imaging parameters such as pinhole edge penetration, detector blur, geometric response, detector and pinhole misalignment, and gamma photon attenuation and scatter can have increasingly noticeable and/or adverse effects on reconstructed image quality. Iterative reconstruction algorithms, the widely-accepted standard for emission tomography, allow modeling of such parameters through a system matrix. For this Monte Carlo simulation study, non-uniform attenuation correction was added to the existing system model. The model was constructed using ray-tracing and further included corrections for edge penetration, detector blur, and geometric aperture response. For each ray passing through different aperture locations, this method attenuates a voxel's contribution to a detector element along the photon path, which is then weighted according to a pinhole penetration model. To lower the computational and memory expenses, symmetry along the detector axes and an incremental storage scheme for the system model were used. For evaluating the nonuniform attenuation correction method, 3 phantoms were designed of which projection images were simulated using Monte Carlo methods. The first phantom was used to examined skin artifacts, the second to simulate attenuation by bone, and the third to generate artifacts of an air-filled space surrounded by soft tissue. In reconstructions without attenuation correction, artifacts were observed with up to a 40% difference in activity. These could be corrected using the implemented method, although in one case overcorrection occurred. Overall, attenuation correction improved reconstruction accuracy of the radioisotope distribution in the presence of structural differences.

原文英語
主出版物標題Medical Imaging 2007
主出版物子標題Physics of Medical Imaging
版本PART 2
DOIs
出版狀態已出版 - 2007
事件Medical Imaging 2007: Physics of Medical Imaging - San Diego, CA, 美國
持續時間: 18 02 200722 02 2007

出版系列

名字Progress in Biomedical Optics and Imaging - Proceedings of SPIE
號碼PART 2
6510
ISSN(列印)1605-7422

Conference

ConferenceMedical Imaging 2007: Physics of Medical Imaging
國家/地區美國
城市San Diego, CA
期間18/02/0722/02/07

指紋

深入研究「A system model for pinhole SPECT simulating edge penetration, detector and pinhole response and non-uniform attenuation」主題。共同形成了獨特的指紋。

引用此