跳至主導覽 跳至搜尋 跳過主要內容

Artificial intelligence for automatic measurement of sagittal vertical axis using resUNet framework

  • Chi Hung Weng
  • , Chih Li Wang
  • , Yu Jui Huang
  • , Yu Cheng Yeh
  • , Chen Ju Fu
  • , Chao Yuan Yeh*
  • , Tsung Ting Tsai
  • *此作品的通信作者
  • Ltd.
  • Chang Gung University

研究成果: 期刊稿件 › 文章 › 同行評審

47 引文 斯高帕斯(Scopus)

摘要

We present an automated method for measuring the sagittal vertical axis (SVA) from lateral radiography of whole spine using a convolutional neural network for keypoint detection (ResUNet) with our improved localization method. The algorithm is robust to various clinical conditions, such as degenerative changes or deformities. The ResUNet was trained and evaluated on 990 standing lateral radiographs taken at Chang Gung Memorial Hospital, Linkou and performs SVA measurement with median absolute error of 1.183 ± 0.166 mm. The 5-mm detection rate of the C7 body and the sacrum are 91% and 87%, respectively. The SVA calculation takes approximately 0.2 s per image. The intra-class correlation coefficient of the SVA estimates between the algorithm and physicians of different years of experience ranges from 0.946 to 0.993, indicating an excellent consistency. The superior performance of the proposed method and its high consistency with physicians proved its usefulness for automatic measurement of SVA in clinical settings.

原文英語
文章編號1826
期刊Journal of Clinical Medicine
卷8
發行號11
DOIs
出版狀態已出版 - 11 2019

文獻附註

Publisher Copyright:
© 2019 by the authors. Licensee MDPI, Basel, Switzerland.

指紋

深入研究「Artificial intelligence for automatic measurement of sagittal vertical axis using resUNet framework」主題。共同形成了獨特的指紋。

引用此