Biocompatibility and mechanical property evaluation of Zr-Ti-Fe based ternary thin film metallic glasses

  • Bih Show Lou
  • , Yung Chin Yang
  • , Jyh Wei Lee*
  • , Li Ting Chen
  • *此作品的通信作者
  • Chang Gung Memorial Hospital
  • National Taipei University of Technology
  • Ming Chi University of Technology
  • Chang Gung University

研究成果: 期刊稿件文章同行評審

30 引文 斯高帕斯(Scopus)

摘要

Thin film metallic glasses (TFMGs) have been heavily studied recently due to their ability to improve structural integrity. These versatile materials can furthermore be engineered to encompass biomedical applications in addition to providing improved hardness and other such uses in altering the base materials. In this work, six Zr-Ti-Fe TFMGs were grown by a magnetron co-sputtering system using pure Fe, Zr, and Ti targets under different target power control. The Fe content of coatings increased from to 17.8 to 49.8 at.%. The amorphous phase of each coating was confirmed by X-ray diffraction and transmission electron microscope techniques, and a featureless cross-section microstructure was found for each coating. Very little pile-up was found after the nanoindentation test. The hardness and elastic modulus of TFMG increased from 5.4 to 10.4 GPa and 73 to 135 GPa, respectively, as the Fe content increased from 17.8 to 49.8 at.%. Each TFMG also had adequate adhesion by HRC-DB test. Good biocompatibility of each TFMG was confirmed with proliferation assay using MG-63 cells. Because of the intrinsic improvement on hardness, and the additional properties of biocompatibility, we can conclude that six thin film metallic glass materials show promising possibilities for biomedical application.

原文英語
頁(從 - 到)512-519
頁數8
期刊Surface and Coatings Technology
320
DOIs
出版狀態已出版 - 25 06 2017

文獻附註

Publisher Copyright:
© 2016 Elsevier B.V.

指紋

深入研究「Biocompatibility and mechanical property evaluation of Zr-Ti-Fe based ternary thin film metallic glasses」主題。共同形成了獨特的指紋。

引用此