Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: A finite element analysis

  • Chun Li Lin
  • , Jen Chyan Wang*
  • , Wen Jen Chang
  • *此作品的通信作者
  • Chang Gung University
  • Kaohsiung Medical University
  • Ta-Hwa Institute of Technology Taiwan

研究成果: 期刊稿件文章同行評審

78 引文 斯高帕斯(Scopus)

摘要

Objective: The aim of this study was to investigate the biomechanical interactions in tooth-implant-supported fixed partial dentures (FPDs) under several loading conditions with different numbers of splinted teeth and connector types (rigid and non-rigid) by adopting the three-dimensional (3D) non-linear finite element (FE) approach. Material and methods: A 3D FE FPD model was constructed containing one Frialit-2 implant in the mandibular second-molar region splinted to the first and second premolars. Frictional contact elements were used to simulate realistic interface conditions within the implant system and the non-rigid connector function. The main effects for each level of the three investigated factors (loading condition, number of splinted teeth and connector type) in terms of the stress values and dissimilar mobility of the natural teeth and implant were computed for all models. Results: The results indicated that load condition was the main factor affecting the stress developed in the implant, bone and prosthesis when comparing the type of connector and the number of splinted teeth. The stress values were significantly reduced in centric or lateral contact situations once the occlusal forces on the pontic were decreased. However, the prosthesis stress for the non-rigid connections was increased more than 3.4-fold relative to the rigid connections. Moreover, the average tooth-to-implant displacement ratios (RTID) with a non-rigid connection were obviously larger than those for rigid connections under axial loading forces. Adding an extra tooth to support a three-unit tooth-implant FPD only exploited its function when the prosthesis withstood lateral occlusal forces. Conclusions: The load condition is the main factor affecting stress distribution in different components (bone, prosthesis and implant) of tooth-implant-supported FPDs. Minimizing the occlusal loading force on the pontic area through selective grinding procedures could reduce the stress values obviously. A non-rigid connector may more efficiently compensate for the dissimilar mobility between the implant and natural teeth under axial loading forces but with the risk of increasing unfavorable stresses in the prosthesis.

原文英語
頁(從 - 到)107-117
頁數11
期刊Clinical Oral Implants Research
19
發行號1
DOIs
出版狀態已出版 - 01 2008
對外發佈

指紋

深入研究「Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: A finite element analysis」主題。共同形成了獨特的指紋。

引用此